Environment - simulationEnvironment: startTime=0 stopTime=432000 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | Using sparse solver for linear system 0, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | Using sparse solver for linear system 3, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2023.10.20 11:01 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-LIVING ZONE-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialTwoPortInterface.mo:21:3-22:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 100000.0, has value: -2.63739e-14" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. stdout | info | 3600.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Calculated Relative Humidity out of range (PsyRhFnTdbWPb) stdout | info | 3600.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Routine=Unknown, Environment=SPAWN-RUNPERIOD, at Simulation time=01/01 00:50 - 00:50 stdout | info | 3600.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Dry-Bulb= -8.26 Humidity Ratio= 2.083E-003 Calculated Relative Humidity [%]= 109.63 stdout | info | 3600.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Relative Humidity being reset to 100.0% assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 41040.000000 | | | | ((slaFlo.port_b.m_flow >= -100000.0 and slaFlo.port_b.m_flow <= 0.0)) --> "Variable violating min/max constraint: -100000.0 <= slaFlo.port_b.m_flow <= 0.0, has value: 4.75489e-31" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialTwoPortInterface.mo:21:3-22:81:writable] | | | | The following assertion has been violated at time 41040.000000 | | | | ((slaFlo.sla.m_flow >= -0.0 and slaFlo.sla.m_flow <= 100000.0)) --> "Variable violating min/max constraint: -0.0 <= slaFlo.sla.m_flow <= 100000.0, has value: -1.58496e-31" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialTwoPortInterface.mo:21:3-22:81:writable] | | | | The following assertion has been violated at time 41040.000000 | | | | ((hea.m_flow >= 0.0 and hea.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= hea.m_flow <= 100000.0, has value: -4.75489e-31" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0217292s reading init.xml | | | | | | 0.00202356s reading info.xml | | | | | | 0.000126908s [ 0.0%] pre-initialization | | | | | | 1.09513s [ 64.4%] initialization | | | | | | 3.6178e-05s [ 0.0%] steps | | | | | | 0.0654989s [ 3.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.234947s [ 13.8%] event-handling | | | | | | 0.0180149s [ 1.1%] overhead | | | | | | 0.286861s [ 16.9%] simulation | | | | | | 1.70062s [100.0%] total | | | | | events | | | | | | 738 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 19068 steps taken | | | | | | 25828 calls of functionODE | | | | | | 9201 evaluations of jacobian | | | | | | 563 error test failures | | | | | | 22 convergence test failures | | | | | | 0.164064s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.97sec EnergyPlus Completed Successfully. stdout | info | 431400.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: ** Warning ** Calculated Relative Humidity out of range (PsyRhFnTdbWPb) stdout | info | 431400.000 RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: