Environment - simulationEnvironment: startTime=0 stopTime=14400 tolerance=1e-06 numberOfIntervals=2500 stepSize=5.76 Regular simulation: ./Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumLoa.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumBoi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:19:3-26:26:writable] | | | | The following assertion has been violated at time 8683.200000 | | | | ((val.res3.y >= 0.0 and val.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= val.res3.y <= 1.0, has value: 1" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 8683.200000 | | | | ((val.filter.y >= 0.0 and val.filter.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= val.filter.y <= 1.0, has value: -1.62489e-09" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0265834s reading init.xml | | | | | | 0.00205958s reading info.xml | | | | | | 0.000251663s [ 0.3%] pre-initialization | | | | | | 0.00072496s [ 0.8%] initialization | | | | | | 9.087e-06s [ 0.0%] steps | | | | | | 0.00313837s [ 3.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0302171s [ 32.2%] event-handling | | | | | | 0.0131412s [ 14.0%] overhead | | | | | | 0.0462253s [ 49.3%] simulation | | | | | | 0.0937077s [100.0%] total | | | | | events | | | | | | 29 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1331 steps taken | | | | | | 1745 calls of functionODE | | | | | | 474 evaluations of jacobian | | | | | | 39 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0115291s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.