Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.Infiltration -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.10.05 12:16 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.10.05 12:16 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((defInf.duc.m_flow >= 0.0 and defInf.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= defInf.duc.m_flow <= 100000.0, has value: -2.63739e-14" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((higInf.duc.m_flow >= 0.0 and higInf.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= higInf.duc.m_flow <= 100000.0, has value: -2.63739e-14" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.079585s reading init.xml | | | | | | 0.00707453s reading info.xml | | | | | | 0.00223297s [ 0.0%] pre-initialization | | | | | | 16.565s [ 96.3%] initialization | | | | | | 2.9305e-05s [ 0.0%] steps | | | | | | 0.0660027s [ 0.4%] solver (excl. callbacks) | | | | | | 0.013368s [ 0.1%] creating output-file | | | | | | 0.150708s [ 0.9%] event-handling | | | | | | 0.0398342s [ 0.2%] overhead | | | | | | 0.36238s [ 2.1%] simulation | | | | | | 17.1995s [100.0%] total | | | | | events | | | | | | 145 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2886 steps taken | | | | | | 3724 calls of functionODE | | | | | | 2134 evaluations of jacobian | | | | | | 19 error test failures | | | | | | 0 convergence test failures | | | | | | 0.175669s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 9.16sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.94sec EnergyPlus Completed Successfully.