Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_10_Buildings.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ThermalZoneHVACWithExhaust.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ThermalZoneHVACWithExhaust.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (exh.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or exh.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ThermalZoneHVACWithExhaust.exh: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((exh.per.haveWMot_nominal or not (exh.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or exh.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ThermalZoneHVACWithExhaust.exh: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0391764s reading init.xml | | | | | | 0.00309218s reading info.xml | | | | | | 0.0010632s [ 3.4%] pre-initialization | | | | | | 0.000684223s [ 2.2%] initialization | | | | | | 2.264e-06s [ 0.0%] steps | | | | | | 0.00239497s [ 7.8%] solver (excl. callbacks) | | | | | | 0.00254749s [ 8.3%] creating output-file | | | | | | 0.000639798s [ 2.1%] event-handling | | | | | | 0.00636434s [ 20.6%] overhead | | | | | | 0.0171703s [ 55.6%] simulation | | | | | | 0.0308666s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1943 steps taken | | | | | | 2619 calls of functionODE | | | | | | 335 evaluations of jacobian | | | | | | 120 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000937028s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.