Environment - simulationEnvironment: startTime=0 stopTime=360000 tolerance=1e-06 numberOfIntervals=2500 stepSize=144 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerWSE -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.hex.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.hex.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerWSE.ets.hex.pum1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.hex.pum1.per.haveWMot_nominal or not (ets.hex.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.hex.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerWSE.ets.hex.pum1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.hex.pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.hex.pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerWSE.ets.hex.pum2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.hex.pum2.per.haveWMot_nominal or not (ets.hex.pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.hex.pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerWSE.ets.hex.pum2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.chi.pumCon.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.chi.pumCon.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerWSE.ets.chi.pumCon: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.chi.pumCon.per.haveWMot_nominal or not (ets.chi.pumCon.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.chi.pumCon.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerWSE.ets.chi.pumCon: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.chi.pumEva.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.chi.pumEva.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerWSE.ets.chi.pumEva: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.chi.pumEva.per.haveWMot_nominal or not (ets.chi.pumEva.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.chi.pumEva.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerWSE.ets.chi.pumEva: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.WSE.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.WSE.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerWSE.ets.WSE.pum1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.WSE.pum1.per.haveWMot_nominal or not (ets.WSE.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.WSE.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerWSE.ets.WSE.pum1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pumChiWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumChiWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerWSE.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumChiWat.per.haveWMot_nominal or not (pumChiWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumChiWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerWSE.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pumHeaWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumHeaWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerWSE.pumHeaWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaWat.per.haveWMot_nominal or not (pumHeaWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumHeaWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerWSE.pumHeaWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 28312.738701. That might raise performance issues, for more information use -lv LOG_LS. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 28312.738701 | | | | ((ets.hex.m2_flow >= 0.0 and ets.hex.m2_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ets.hex.m2_flow <= 100000.0, has value: -1.88193e-20" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Experimental/DHC/Networks/BaseClasses/PartialDistribution2Pipe.mo:81:3-85:55:writable] | | | | The following assertion has been violated at time 28312.738701 | | | | ((ets.colHeaWat.mCon_flow[2] >= 0.0 and ets.colHeaWat.mCon_flow[2] <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ets.colHeaWat.mCon_flow[2] <= 100000.0, has value: -4.42354e-20" stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 29138.083594. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 64312.738701. That might raise performance issues, for more information use -lv LOG_LS. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 64800.000000 | | | | ((ets.WSE.hex.m2_flow >= 0.0 and ets.WSE.hex.m2_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ets.WSE.hex.m2_flow <= 100000.0, has value: -3.67391e-20" assert | info | The following assertion has been violated at time 64800.000000 | | | | (($cse87 >= -100000.0 and $cse87 <= -0.0)) --> "Variable violating min/max constraint: -100000.0 <= $cse87 <= -0.0, has value: 3.67391e-20" stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 100312.738701. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 101134.664647. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 127685.113211. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 135454.794304. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 137760.000027. That might raise performance issues, for more information use -lv LOG_LS. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/HeatExchangers/BaseClasses/PartialEffectiveness.mo:24:3-30:39:writable] | | | | The following assertion has been violated at time 137760.000027 | | | | ((ets.WSE.hex.C2_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= ets.WSE.hex.C2_flow, has value: -2.89794e-319" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/HeatExchangers/BaseClasses/PartialEffectiveness.mo:31:3-32:38:writable] | | | | The following assertion has been violated at time 137760.000027 | | | | ((ets.WSE.hex.CMin_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= ets.WSE.hex.CMin_flow, has value: -2.89794e-319" stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 149371.832702. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 158460.403455. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 163040.256434. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 172312.738701. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 173133.621082. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 204712.738701. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 205760.365374. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 241260.000000. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 253025.725696. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 276712.738701. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 277740.000000. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 288275.137751. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 298636.842135. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 313734.357347. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 325261.612760. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 333528.487931. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 348712.738701. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 349751.617565. That might raise performance issues, for more information use -lv LOG_LS. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 356676.523741. That might raise performance issues, for more information use -lv LOG_LS. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.158731s reading init.xml | | | | | | 0.0127595s reading info.xml | | | | | | 0.00586619s [ 0.1%] pre-initialization | | | | | | 0.00346448s [ 0.0%] initialization | | | | | | 0.00159904s [ 0.0%] steps | | | | | | 0.722608s [ 6.3%] solver (excl. callbacks) | | | | | | 0.0827756s [ 0.7%] creating output-file | | | | | | 1.39s [ 12.1%] event-handling | | | | | | 0.189495s [ 1.6%] overhead | | | | | | 9.10592s [ 79.2%] simulation | | | | | | 11.5017s [100.0%] total | | | | | events | | | | | | 245 state events | | | | | | 6001 time events | | | | | solver: dassl | | | | | | 86865 steps taken | | | | | | 104355 calls of functionODE | | | | | | 64412 evaluations of jacobian | | | | | | 602 error test failures | | | | | | 3 convergence test failures | | | | | | 7.79996s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.