Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_10_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Validation.Controller -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel5.y)) --> "Warning: the hot-duct damper is leaking." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel3.y)) --> "Warning: the cold-duct damper is leaking." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 2160.000000 | | | | ((duaDucCon.gre.greHys.y)) --> "Warning: the sum of minimum flow and heating maximum flow is greater than the cooling maximum flow." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 2160.000000 | | | | ((duaDucCon.actAirSet.gre.greHys.y)) --> "Warning: the sum of minimum flow and heating maximum flow is greater than the cooling maximum flow." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 12080.000001 | | | | ((not duaDucCon.ala.truDel4.y)) --> "Warning: hot-duct airflow sensor should be calibrated." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 12080.000001 | | | | ((not duaDucCon.ala.truDel2.y)) --> "Warning: cold-duct airflow sensor should be calibrated." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0248851s reading init.xml | | | | | | 0.00196912s reading info.xml | | | | | | 0.00118699s [ 1.1%] pre-initialization | | | | | | 0.000275367s [ 0.3%] initialization | | | | | | 1.6982e-05s [ 0.0%] steps | | | | | | 0.0181894s [ 17.3%] solver (excl. callbacks) | | | | | | 0.00901739s [ 8.6%] creating output-file | | | | | | 0.0381993s [ 36.3%] event-handling | | | | | | 0.00112043s [ 1.1%] overhead | | | | | | 0.0372386s [ 35.4%] simulation | | | | | | 0.105244s [100.0%] total | | | | | events | | | | | | 53 state events | | | | | | 724 time events | | | | | solver: dassl | | | | | | 11585 steps taken | | | | | | 13382 calls of functionODE | | | | | | 10058 evaluations of jacobian | | | | | | 53 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00972088s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.