Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./Annex60_1.0.0_Annex60.Fluid.Movers.Validation.FlowControlled_dp -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:347:3-356:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floMacSta.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:347:3-356:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floMacDyn.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00970903s reading init.xml | | | | | | 0.000961994s reading info.xml | | | | | | 0.000105408s [ 0.4%] pre-initialization | | | | | | 0.00031431s [ 1.2%] initialization | | | | | | 3.286e-06s [ 0.0%] steps | | | | | | 0.000757073s [ 2.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000364959s [ 1.3%] event-handling | | | | | | 0.00355337s [ 13.1%] overhead | | | | | | 0.0220133s [ 81.2%] simulation | | | | | | 0.0271117s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 111 steps taken | | | | | | 173 calls of functionODE | | | | | | 61 evaluations of jacobian | | | | | | 6 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000229716s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.