Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./AixLib_latest_AixLib.Fluid.Movers.Validation.FlowControlled_dpSystem -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floConDp.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floConDpSystem.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.750000 | | | | ((heaCoi2.m_flow >= 0.0 and heaCoi2.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= heaCoi2.m_flow <= 100000.0, has value: -2.5833e-14" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.750000 | | | | ((heaCoi1.m_flow >= 0.0 and heaCoi1.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= heaCoi1.m_flow <= 100000.0, has value: -3.45439e-15" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0185317s reading init.xml | | | | | | 0.00177991s reading info.xml | | | | | | 0.000141455s [ 0.3%] pre-initialization | | | | | | 0.000411983s [ 0.9%] initialization | | | | | | 5.099e-06s [ 0.0%] steps | | | | | | 0.00104584s [ 2.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000429145s [ 1.0%] event-handling | | | | | | 0.00663675s [ 14.9%] overhead | | | | | | 0.0359604s [ 80.6%] simulation | | | | | | 0.0446306s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 84 steps taken | | | | | | 91 calls of functionODE | | | | | | 80 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000479715s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.