Environment - simulationEnvironment: startTime=0 stopTime=29600 tolerance=1e-06 numberOfIntervals=29600 stepSize=1 Regular simulation: ./AixLib_latest_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationEta.txt" stdout | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationOda.txt" stdout | info | ... loading "Result" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationResult.txt" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Sensors/RelativeHumidityTwoPort.mo:5:3-11:26:writable] | | | | The following assertion has been violated at time 4810.500000 | | | | ((enthalpyExchanger.airDuct1.senRelHum.phi >= 0.01 and enthalpyExchanger.airDuct1.senRelHum.phi <= 0.99)) --> "Variable violating min/max constraint: 0.01 <= enthalpyExchanger.airDuct1.senRelHum.phi <= 0.99, has value: 0.991496" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.1047s reading init.xml | | | | | | 0.00865723s reading info.xml | | | | | | 0.000722484s [ 0.0%] pre-initialization | | | | | | 0.0035161s [ 0.0%] initialization | | | | | | 0.000132899s [ 0.0%] steps | | | | | | 0.275551s [ 1.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0605449s [ 0.4%] event-handling | | | | | | 0.480559s [ 3.0%] overhead | | | | | | 15.139s [ 94.9%] simulation | | | | | | 15.96s [100.0%] total | | | | | events | | | | | | 72 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 7361 steps taken | | | | | | 10157 calls of functionODE | | | | | | 1176 evaluations of jacobian | | | | | | 222 error test failures | | | | | | 2 convergence test failures | | | | | | 3.461s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.