Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-05 numberOfIntervals=2880 stepSize=60 Regular simulation: ./AixLib_latest_AixLib.Fluid.DistrictHeatingCooling.Supplies.Examples.DHCSupplyHeaterCoolerStorage -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation1.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation1.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation2.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation2.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | debug | New front position is not smaller then previous first node. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | debug | New end position is not bigger then previous last node. stdout | info | model terminate | Simulation terminated by an assert at time: 32.7731 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0738232s reading init.xml | | | | | | 0.0059385s reading info.xml | | | | | | 0.000487143s [ 8.3%] pre-initialization | | | | | | 0.000918683s [ 15.6%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00027025s [ 4.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00150349s [ 25.5%] event-handling | | | | | | 2.163e-05s [ 0.4%] overhead | | | | | | 0.00269319s [ 45.7%] simulation | | | | | | 0.00589438s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1 steps taken | | | | | | 1 calls of functionODE | | | | | | 1 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00159337s time of jacobian evaluation