Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./AixLib_latest_AixLib.Airflow.Multizone.Examples.CO2TransportStep -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenTop.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenTop can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'AixLib.Fluid.MixingVolumes`. | | | | See AixLib.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenTop." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenWes.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenWes can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'AixLib.Fluid.MixingVolumes`. | | | | See AixLib.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenWes." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenEas.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenEas can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'AixLib.Fluid.MixingVolumes`. | | | | See AixLib.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenEas." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0136123s reading init.xml | | | | | | 0.000896782s reading info.xml | | | | | | 0.000158898s [ 0.8%] pre-initialization | | | | | | 0.000246914s [ 1.2%] initialization | | | | | | 2.996e-06s [ 0.0%] steps | | | | | | 0.00128131s [ 6.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0029405s [ 14.1%] event-handling | | | | | | 0.00292169s [ 14.0%] overhead | | | | | | 0.0132709s [ 63.7%] simulation | | | | | | 0.0208232s [100.0%] total | | | | | events | | | | | | 6 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 158 steps taken | | | | | | 247 calls of functionODE | | | | | | 82 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 1 convergence test failures | | | | | | 0.000609459s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.