/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IBPSA_latest_IBPSA_Obsolete_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured_fmu --startTime=0 --stopTime=600 --timeout=50 --tolerance=1e-06 IBPSA_latest_IBPSA_Obsolete_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured.fmu assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.etaHyd, has value: -5.22765e-26" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.heaDis.etaHyd, has value: -9.75828e-22" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan3.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan3.eff.yMot, has value: -2.01147e-25" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Obsolete/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan4.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan4.etaHyd, has value: -5.22765e-26" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan4.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan4.heaDis.etaHyd, has value: -9.75828e-22" info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IBPSA_latest_IBPSA.Obsolete.Fluid.Movers.Preconfigured.Validation.ControlledFlowMachinePreconfigured/temp_IBPSA_latest_IBPSA_Obsolete_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured_fmu/model-5rat2di8/temp/0001_IBPSA_latest_IBPSA_Obsolete_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.IBPSA_latest_IBPSA_Obsolete_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured"