/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.TwoPhaseFlow.Test_HEXvle2vle_L3_2ph_CH_simple_headers_res.mat --tempDir=temp_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers_fmu --startTime=0 --stopTime=12000 --timeout=50 --tolerance=1e-05 ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.TwoPhaseFlow.Test_HEXvle2vle_L3_2ph_CH_simple_headers/temp_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers_fmu/model-qutbk2dt/temp/0001_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 assert | debug | Model error: Argument of log(abs(hex.tubes.heattransfer.Delta_T_U) / (abs(hex.tubes.heattransfer.Delta_T_L) + 1e-09)) was 0 should be > 0 stdout | warning | Non-Linear Solver try to handle a problem with a called assert. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.TwoPhaseFlow.Test_HEXvle2vle_L3_2ph_CH_simple_headers/temp_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers_fmu/model-qutbk2dt/temp/0001_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 assert | debug | Model error: Argument of log(abs(hex.tubes.heattransfer.Delta_T_U) / (abs(hex.tubes.heattransfer.Delta_T_L) + 1e-09)) was 0 should be > 0 assert | debug | Solving non-linear system 867 failed at time=0. | | | | For more information please use -lv LOG_NLS. assert | error | Failed to solve the initialization problem with global homotopy with equidistant step size. assert | debug | Unable to solve initialization problem. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ClaRa_ClaRa.Components.VolumesValvesFittings.Pipes.Check.TwoPhaseFlow.Test_HEXvle2vle_L3_2ph_CH_simple_headers/temp_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers_fmu/model-qutbk2dt/temp/0001_ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers (logFmi2Call): fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.ClaRa_ClaRa_Components_VolumesValvesFittings_Pipes_Check_TwoPhaseFlow_Test_HEXvle2vle_L3_2ph_CH_simple_headers" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 2 warnings info: 4 errors