/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms_res.mat --tempDir=temp_Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.fmu info: model doesn't contain any continuous state info: Result file: Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms_res.mat (bufferSize=1) info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.higTemAla2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.higTemAla3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla4.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla5.message will not be stored in the result file, because the signal type is not supported assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 1601.348000 | | | | ((not zonAla.tenMinDur4.y)) --> "Warning: the zone CO2 concentration exceeds setpoint plus 10%." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 3759.514000 | | | | ((zonAla.not3.y)) --> "Warning: zone temperature is 2 degC lower than the heating setpoint" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 3910.450000 | | | | ((zonAla.not4.y)) --> "Warning: zone temperature is 3 degC lower than the heating setpoint" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 4337.398000 | | | | ((zonAla.not5.y)) --> "Warning: the zone CO2 concentration exceeds 600 ppm in unoccupied mode. The CO2 sensor may be out of calibration." error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors