Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.7763/0.7763, allocations: 150.9 MB / 166.7 MB, free: 14.66 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.000324/0.0003241, allocations: 11.98 kB / 204.8 MB, free: 10.07 MB / 174.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1468/0.1471, allocations: 31.33 MB / 236.1 MB, free: 5.441 MB / 190.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC): time 1.579/1.726, allocations: 371.6 MB / 0.5935 GB, free: 15.54 MB / 494.1 MB Notification: Performance of NFInst.instExpressions: time 0.5525/2.278, allocations: 223.5 MB / 0.8117 GB, free: 15.65 MB / 0.6075 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01461/2.293, allocations: 172.8 kB / 0.8119 GB, free: 15.62 MB / 0.6075 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/SinkP.mo:16:3-18:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:89:3-90:45:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:91:3-92:46:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:99:3-100:48:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:101:3-102:43:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceQ.mo:24:3-25:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/SourceQ.mo:17:3-18:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01409/2.307, allocations: 3.716 MB / 0.8155 GB, free: 12.78 MB / 0.6075 GB Notification: Performance of NFTyping.typeBindings: time 0.03204/2.339, allocations: 12.02 MB / 0.8273 GB, free: 5.484 MB / 0.6075 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.06131/2.401, allocations: 23.92 MB / 0.8506 GB, free: 1.227 MB / 0.6231 GB Notification: Performance of NFFlatten.flatten: time 0.0813/2.482, allocations: 83.16 MB / 0.9319 GB, free: 15.74 MB / 0.7169 GB Notification: Performance of NFFlatten.resolveConnections: time 0.04081/2.523, allocations: 28.39 MB / 0.9596 GB, free: 3.676 MB / 0.7325 GB Notification: Performance of NFEvalConstants.evaluate: time 0.7109/3.234, allocations: 28.27 MB / 0.9872 GB, free: 51.62 MB / 0.7482 GB Notification: Performance of NFSimplifyModel.simplify: time 0.0522/3.286, allocations: 32.46 MB / 1.019 GB, free: 50.04 MB / 0.7482 GB Notification: Performance of NFPackage.collectConstants: time 0.02381/3.31, allocations: 6.033 MB / 1.025 GB, free: 50.04 MB / 0.7482 GB Notification: Performance of NFFlatten.collectFunctions: time 0.06283/3.373, allocations: 32.47 MB / 1.056 GB, free: 50.03 MB / 0.7482 GB Notification: Performance of NFScalarize.scalarize: time 0.02898/3.402, allocations: 17.51 MB / 1.074 GB, free: 47.83 MB / 0.7482 GB Notification: Performance of NFVerifyModel.verify: time 0.05691/3.459, allocations: 25.62 MB / 1.099 GB, free: 32.84 MB / 0.7482 GB Notification: Performance of NFConvertDAE.convert: time 0.07035/3.529, allocations: 60.44 MB / 1.158 GB, free: 15.23 MB / 0.7794 GB Notification: Performance of FrontEnd - DAE generated: time 9.698e-06/3.529, allocations: 4.812 kB / 1.158 GB, free: 15.22 MB / 0.7794 GB Notification: Performance of FrontEnd: time 1.783e-06/3.529, allocations: 0 / 1.158 GB, free: 15.22 MB / 0.7794 GB Notification: Performance of Transformations before backend: time 0.002407/3.532, allocations: 0.8438 kB / 1.158 GB, free: 15.22 MB / 0.7794 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 10686 * Number of variables: 10686 Notification: Performance of Generate backend data structure: time 0.2313/3.763, allocations: 56.21 MB / 1.213 GB, free: 7.289 MB / 0.8263 GB Notification: Performance of prepare preOptimizeDAE: time 4.661e-05/3.763, allocations: 12.03 kB / 1.213 GB, free: 7.277 MB / 0.8263 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0215/3.784, allocations: 4.105 MB / 1.217 GB, free: 3.129 MB / 0.8263 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.04274/3.827, allocations: 16.34 MB / 1.233 GB, free: 3.855 MB / 0.8419 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.01739/3.845, allocations: 11.99 MB / 1.244 GB, free: 6.148 MB / 0.8575 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01774/3.862, allocations: 2.862 MB / 1.247 GB, free: 3.285 MB / 0.8575 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.9201/4.782, allocations: 70.05 MB / 1.315 GB, free: 176.9 MB / 0.9045 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001715/4.784, allocations: 41.19 kB / 1.315 GB, free: 176.9 MB / 0.9045 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.01553/4.8, allocations: 1.136 MB / 1.317 GB, free: 176.9 MB / 0.9045 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001595/4.801, allocations: 1.313 MB / 1.318 GB, free: 176.9 MB / 0.9045 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.222/5.023, allocations: 86.88 MB / 1.403 GB, free: 166.1 MB / 0.9045 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.9028/5.926, allocations: 257 MB / 1.654 GB, free: 468.9 MB / 0.9829 GB Notification: Performance of preOpt comSubExp (simulation): time 0.1599/6.086, allocations: 74.61 MB / 1.727 GB, free: 455.2 MB / 0.9829 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.1035/6.19, allocations: 49.95 MB / 1.775 GB, free: 436.3 MB / 0.9829 GB Notification: Performance of preOpt evalFunc (simulation): time 0.2265/6.416, allocations: 147.2 MB / 1.919 GB, free: 292.4 MB / 0.9829 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.1298/6.546, allocations: 54.73 MB / 1.973 GB, free: 237.5 MB / 0.9829 GB Notification: Performance of pre-optimization done (n=7248): time 0.0001605/6.546, allocations: 0 / 1.973 GB, free: 237.5 MB / 0.9829 GB Notification: Performance of matching and sorting (n=7256): time 1.43/7.976, allocations: 343.1 MB / 2.308 GB, free: 440.3 MB / 0.9829 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0005126/7.977, allocations: 0.9785 MB / 2.309 GB, free: 439.6 MB / 0.9829 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.02151/7.998, allocations: 10.67 MB / 2.319 GB, free: 434.2 MB / 0.9829 GB Notification: Performance of collectPreVariables (initialization): time 0.01395/8.012, allocations: 0.655 MB / 2.32 GB, free: 433.6 MB / 0.9829 GB Notification: Performance of collectInitialEqns (initialization): time 0.00819/8.021, allocations: 7.692 MB / 2.327 GB, free: 427 MB / 0.9829 GB Notification: Performance of collectInitialBindings (initialization): time 0.0314/8.052, allocations: 24.35 MB / 2.351 GB, free: 405.8 MB / 0.9829 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.04919/8.101, allocations: 9.408 MB / 2.36 GB, free: 400.7 MB / 0.9829 GB Notification: Performance of setup shared object (initialization): time 5.276e-05/8.101, allocations: 309.1 kB / 2.36 GB, free: 400.4 MB / 0.9829 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.1094/8.211, allocations: 43.66 MB / 2.403 GB, free: 377.9 MB / 0.9829 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.121/8.332, allocations: 49.87 MB / 2.452 GB, free: 333.6 MB / 0.9829 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 1.352/9.684, allocations: 288.1 MB / 2.733 GB, free: 396.7 MB / 0.9829 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0002545/9.684, allocations: 26.44 kB / 2.733 GB, free: 396.7 MB / 0.9829 GB Notification: Performance of matching and sorting (n=8082) (initialization): time 0.4481/10.13, allocations: 148.5 MB / 2.878 GB, free: 346.9 MB / 0.9829 GB Notification: Performance of prepare postOptimizeDAE: time 0.000335/10.13, allocations: 105.2 kB / 2.878 GB, free: 346.8 MB / 0.9829 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0008337/10.13, allocations: 201.6 kB / 2.878 GB, free: 346.8 MB / 0.9829 GB Notification: Performance of postOpt tearingSystem (initialization): time 5.188/15.32, allocations: 2.231 GB / 5.109 GB, free: 138.8 MB / 0.9829 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01876/15.34, allocations: 3.291 MB / 5.112 GB, free: 136.5 MB / 0.9829 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.8304/16.17, allocations: 192.6 MB / 5.3 GB, free: 416.7 MB / 0.9829 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.09098/16.26, allocations: 6.486 MB / 5.307 GB, free: 416.1 MB / 0.9829 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01639/16.28, allocations: 1.932 MB / 5.309 GB, free: 415.8 MB / 0.9829 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP3.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP3.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurMP3.TwoPhaseFlowPipe.Q[1] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 414 * Number of states: 0 () * Number of discrete variables: 269 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,$whenCondition1,SourceFumees.C.b,vanne_entree_TurbineMP.C2.b,vanne_entree_TurbineMP.C1.a,MelangeurPreTMP.Ce3.a,MelangeurPreTMP.Cs.b,MelangeurPreTMP.Ce2.a,MelangeurPreTMP.Ce1.a,VolumePreTHP.Cs3.b,VolumePreTHP.Cs2.b,VolumePreTHP.Cs1.b,VolumePreTHP.Ce.a,Vanne_alimentationMPHP2.C2.b,Vanne_alimentationMPHP2.C1.a,Vanne_alimentationMPHP1.C2.b,Vanne_alimentationMPHP1.C1.a,VolumeECO_HP2_3.Ce3.a,VolumeECO_HP2_3.Cs.b,VolumeECO_HP2_3.Ce2.a,VolumeECO_HP2_3.Ce1.a,VolumeECO_HP1_2.Ce3.a,VolumeECO_HP1_2.Cs.b,VolumeECO_HP1_2.Ce2.a,VolumeECO_HP1_2.Ce1.a,vanne_entree_TurbineHP.C2.b,vanne_entree_TurbineHP.C1.a,lumpedStraightPipeK2.C2.b,lumpedStraightPipeK2.C1.a,CapteurDebitVapCondenseur.C2.b,CapteurDebitVapCondenseur.C1.a,CapteurDebitEauCondenseur.C2.b,CapteurDebitEauCondenseur.C1.a,CapteurDebitEauBPsortie.C2.b,CapteurDebitEauBPsortie.C1.a,CapteurDebitEauBP.C2.b,CapteurDebitEauBP.C1.a,CapteurDebitVapBP.C2.b,CapteurDebitVapBP.C1.a,CapteurDebitVapMP.C2.b,CapteurDebitVapMP.C1.a,CapteurDebitEauMP.C2.b,CapteurDebitEauMP.C1.a,CapteurDebitEauHP.C2.b,CapteurDebitEauHP.C1.a,CapteurDebitVapHP.C2.b,CapteurDebitVapHP.C1.a,vanne_extraction.C2.b,vanne_extraction.C1.a,perteChargeK2.C2.b,perteChargeK2.C1.a,PompeAlimBP.C2.b,PompeAlimBP.C1.a,perteChargeK.C2.b,perteChargeK.C1.a,perteChargeK8.C2.b,perteChargeK8.C1.a,perteChargeK3.C2.b,perteChargeK3.C1.a,PerteChargeZero2.C2.b,PerteChargeZero2.C1.a,DoubleDebitBP.Cs.b,DoubleDebitBP.Ce.a,MoitieDebitBP.Cs.b,MoitieDebitBP.Ce.a,PompeAlimHP.C2.b,PompeAlimHP.C1.a,PompeAlimMP.C2.b,PompeAlimMP.C1.a,VolumeAlimMPHP.Cs2.b,VolumeAlimMPHP.Cs1.b,VolumeAlimMPHP.Ce2.a,VolumeAlimMPHP.Ce1.a,perteChargeKCond1.C2.b,perteChargeKCond1.C1.a,VolumeCond1.Ce3.a,VolumeCond1.Cs.b,VolumeCond1.Ce2.a,VolumeCond1.Ce1.a,perteChargeK1.C2.b,perteChargeK1.C1.a,PuitsCaloporteur.C.a,SourceCaloporteur.C.b,Condenseur.Cse.b,Condenseur.Cee.a,Condenseur.Cl.b,Condenseur.Cv.a,MoitieDebitHP.Cs.b,MoitieDebitHP.Ce.a,DoubleDebitMP.Cs.b,DoubleDebitMP.Ce.a,DoubleDebitHP.Cs.b,DoubleDebitHP.Ce.a,TurbineBP.Cs.b,TurbineBP.Ce.a,MelangeurPostTMP1.Ce3.a,MelangeurPostTMP1.Cs.b,MelangeurPostTMP1.Ce2.a,MelangeurPostTMP1.Ce1.a,TurbineMP.Cs.b,TurbineMP.Ce.a,TurbineHP.Cs.b,TurbineHP.Ce.a,EconomiseurBP.TwoPhaseFlowPipe.C2.b,EconomiseurBP.TwoPhaseFlowPipe.C1.a,EconomiseurBP.ExchangerFlueGasesMetal.C2.b,EconomiseurBP.ExchangerFlueGasesMetal.C1.a,PuitsFumees.C.a,SurchauffeurBP.TwoPhaseFlowPipe.C2.b,SurchauffeurBP.TwoPhaseFlowPipe.C1.a,SurchauffeurBP.ExchangerFlueGasesMetal.C2.b,SurchauffeurBP.ExchangerFlueGasesMetal.C1.a,Vanne_alimentationMPHP.C2.b,Vanne_alimentationMPHP.C1.a,EvaporateurBP.TwoPhaseFlowPipe.C2.b,EvaporateurBP.TwoPhaseFlowPipe.C1.a,EvaporateurBP.ExchangerFlueGasesMetal.C2.b,EvaporateurBP.ExchangerFlueGasesMetal.C1.a,VolumeEvapBP.Ce3.a,VolumeEvapBP.Cs.b,VolumeEvapBP.Ce2.a,VolumeEvapBP.Ce1.a,GainChargeBP.C2.b,GainChargeBP.C1.a,vanne_alimentationBP.C2.b,vanne_alimentationBP.C1.a,vanne_vapeurBP.C2.b,vanne_vapeurBP.C1.a,BallonBP.Cs.b,BallonBP.Ce3.a,BallonBP.Ce2.a,BallonBP.Cv.b,BallonBP.Cd.b,BallonBP.Cm.a,BallonBP.Ce1.a,SurchauffeurMP3.TwoPhaseFlowPipe.C2.b,SurchauffeurMP3.TwoPhaseFlowPipe.C1.a,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurMP2.TwoPhaseFlowPipe.C2.b,SurchauffeurMP2.TwoPhaseFlowPipe.C1.a,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.a,MelangeurHPMP.Cs2.b,MelangeurHPMP.Cs1.b,MelangeurHPMP.Ce2.a,MelangeurHPMP.Ce1.a,SurchauffeurMP1.TwoPhaseFlowPipe.C2.b,SurchauffeurMP1.TwoPhaseFlowPipe.C1.a,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.a,EconomiseurMP.TwoPhaseFlowPipe.C2.b,EconomiseurMP.TwoPhaseFlowPipe.C1.a,EconomiseurMP.ExchangerFlueGasesMetal.C2.b,EconomiseurMP.ExchangerFlueGasesMetal.C1.a,VolumeEvapMP.Ce3.a,VolumeEvapMP.Cs.b,VolumeEvapMP.Ce2.a,VolumeEvapMP.Ce1.a,GainChargeMP.C2.b,GainChargeMP.C1.a,EvaporateurMP.TwoPhaseFlowPipe.C2.b,EvaporateurMP.TwoPhaseFlowPipe.C1.a,EvaporateurMP.ExchangerFlueGasesMetal.C2.b,EvaporateurMP.ExchangerFlueGasesMetal.C1.a,vanne_vapeurMP.C2.b,vanne_vapeurMP.C1.a,vanne_alimentationMP.C2.b,vanne_alimentationMP.C1.a,BallonMP.Cs.b,BallonMP.Ce3.a,BallonMP.Ce2.a,BallonMP.Cv.b,BallonMP.Cd.b,BallonMP.Cm.a,BallonMP.Ce1.a,SurchauffeurHP3.TwoPhaseFlowPipe.C2.b,SurchauffeurHP3.TwoPhaseFlowPipe.C1.a,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP2.TwoPhaseFlowPipe.C2.b,SurchauffeurHP2.TwoPhaseFlowPipe.C1.a,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.a,EconomiseurHP1.TwoPhaseFlowPipe.C2.b,EconomiseurHP1.TwoPhaseFlowPipe.C1.a,EconomiseurHP1.ExchangerFlueGasesMetal.C2.b,EconomiseurHP1.ExchangerFlueGasesMetal.C1.a,EconomiseurHP2.TwoPhaseFlowPipe.C2.b,EconomiseurHP2.TwoPhaseFlowPipe.C1.a,EconomiseurHP2.ExchangerFlueGasesMetal.C2.b,EconomiseurHP2.ExchangerFlueGasesMetal.C1.a,EconomiseurHP3.TwoPhaseFlowPipe.C2.b,EconomiseurHP3.TwoPhaseFlowPipe.C1.a,EconomiseurHP3.ExchangerFlueGasesMetal.C2.b,EconomiseurHP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP1.TwoPhaseFlowPipe.C2.b,SurchauffeurHP1.TwoPhaseFlowPipe.C1.a,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.a,EconomiseurHP4.TwoPhaseFlowPipe.C2.b,EconomiseurHP4.TwoPhaseFlowPipe.C1.a,EconomiseurHP4.ExchangerFlueGasesMetal.C2.b,EconomiseurHP4.ExchangerFlueGasesMetal.C1.a,EvaporateurHP.TwoPhaseFlowPipe.C2.b,EvaporateurHP.TwoPhaseFlowPipe.C1.a,EvaporateurHP.ExchangerFlueGasesMetal.C2.b,EvaporateurHP.ExchangerFlueGasesMetal.C1.a,VolumeEvapHP.Ce3.a,VolumeEvapHP.Cs.b,VolumeEvapHP.Ce2.a,VolumeEvapHP.Ce1.a,GainChargeHP.C2.b,GainChargeHP.C1.a,vanne_vapeurHP.C2.b,vanne_vapeurHP.C1.a,vanne_alimentationHP.C2.b,vanne_alimentationHP.C1.a,BallonHP.Cs.b,BallonHP.Ce3.a,BallonHP.Ce2.a,BallonHP.Cv.b,BallonHP.Cd.b,BallonHP.Cm.a,BallonHP.Ce1.a,MelangeurPreTMP.Ce3.b,MelangeurPreTMP.Ce2.b,VolumePreTHP.Cs2.a,VolumePreTHP.Cs1.a,VolumeECO_HP2_3.Ce3.b,VolumeECO_HP2_3.Ce2.b,VolumeECO_HP1_2.Ce3.b,VolumeECO_HP1_2.Ce2.b,VolumeAlimMPHP.Ce2.b,VolumeCond1.Ce2.b,VolumeCond1.Ce1.b,MelangeurPostTMP1.Ce3.b,VolumeEvapBP.Ce3.b,VolumeEvapBP.Ce2.b,BallonBP.Ce3.b,BallonBP.Ce2.b,MelangeurHPMP.Cs1.a,VolumeEvapMP.Ce3.b,VolumeEvapMP.Ce2.b,BallonMP.Cs.a,BallonMP.Ce3.b,BallonMP.Ce2.b,VolumeEvapHP.Ce3.b,VolumeEvapHP.Ce2.b,BallonHP.Cs.a,BallonHP.Ce3.b,BallonHP.Ce2.b) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1368): * Single equations (assignments): 1299 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 49 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 13 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 5 systems {1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 2 systems {(4,1,62.5%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 11 systems {(1,1), (1,15), (1,1), (1,3), (2,11), (1,15), (318,2904), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.04475/16.32, allocations: 8.88 MB / 5.317 GB, free: 411.7 MB / 0.9829 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.02127/16.34, allocations: 2.956 MB / 5.32 GB, free: 411.7 MB / 0.9829 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.4689/16.81, allocations: 158.9 MB / 5.475 GB, free: 277 MB / 0.9829 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.4165/17.23, allocations: 140.6 MB / 5.613 GB, free: 136 MB / 0.9829 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0003948/17.23, allocations: 30.95 kB / 5.613 GB, free: 136 MB / 0.9829 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001499/17.23, allocations: 278.9 kB / 5.613 GB, free: 135.7 MB / 0.9829 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.9615/18.19, allocations: 326.9 MB / 5.932 GB, free: 290.6 MB / 0.9829 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.001063/18.19, allocations: 115.9 kB / 5.932 GB, free: 290.4 MB / 0.9829 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.0791/18.27, allocations: 16.13 MB / 5.948 GB, free: 274.9 MB / 0.9829 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.1222/18.4, allocations: 45.1 MB / 5.992 GB, free: 230.8 MB / 0.9829 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.01597/18.41, allocations: 1.896 MB / 5.994 GB, free: 228.9 MB / 0.9829 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.7184/19.13, allocations: 338.4 MB / 6.324 GB, free: 359.2 MB / 0.9829 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 7.454e-06/19.13, allocations: 14.66 kB / 6.324 GB, free: 359.2 MB / 0.9829 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.56/19.69, allocations: 207.7 MB / 6.527 GB, free: 225.9 MB / 0.9829 GB Notification: Performance of postOpt removeConstants (simulation): time 0.0343/19.72, allocations: 11.61 MB / 6.539 GB, free: 214.9 MB / 0.9829 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.02017/19.74, allocations: 1.168 MB / 6.54 GB, free: 213.8 MB / 0.9829 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.06212/19.81, allocations: 6.628 MB / 6.546 GB, free: 207.3 MB / 0.9829 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0217/19.83, allocations: 4.129 MB / 6.55 GB, free: 203.2 MB / 0.9829 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01537/19.84, allocations: 2.046 MB / 6.552 GB, free: 201.2 MB / 0.9829 GB Notification: Performance of sorting global known variables: time 0.01217/19.86, allocations: 6.88 MB / 6.559 GB, free: 194.4 MB / 0.9829 GB Notification: Performance of sort global known variables: time 6.82e-07/19.86, allocations: 0 / 6.559 GB, free: 194.4 MB / 0.9829 GB Notification: Performance of remove unused functions: time 0.06492/19.92, allocations: 15.47 MB / 6.574 GB, free: 179.1 MB / 0.9829 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 40 * Number of states: 249 (BallonHP.P,BallonHP.hl,BallonHP.hv,BallonHP.Tp,BallonHP.Vv,VolumeEvapHP.h,EvaporateurHP.ExchangerWall.Tp[1],EvaporateurHP.ExchangerWall.Tp[2],EvaporateurHP.ExchangerWall.Tp[3],EvaporateurHP.TwoPhaseFlowPipe.P[2],EvaporateurHP.TwoPhaseFlowPipe.P[3],EvaporateurHP.TwoPhaseFlowPipe.P[4],EvaporateurHP.TwoPhaseFlowPipe.Q[1],EvaporateurHP.TwoPhaseFlowPipe.Q[2],EvaporateurHP.TwoPhaseFlowPipe.Q[3],EvaporateurHP.TwoPhaseFlowPipe.Q[4],EvaporateurHP.TwoPhaseFlowPipe.h[2],EvaporateurHP.TwoPhaseFlowPipe.h[3],EvaporateurHP.TwoPhaseFlowPipe.h[4],EconomiseurHP4.ExchangerWall.Tp[1],EconomiseurHP4.ExchangerWall.Tp[2],EconomiseurHP4.ExchangerWall.Tp[3],EconomiseurHP4.TwoPhaseFlowPipe.P[2],EconomiseurHP4.TwoPhaseFlowPipe.P[3],EconomiseurHP4.TwoPhaseFlowPipe.P[4],EconomiseurHP4.TwoPhaseFlowPipe.Q[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[3],EconomiseurHP4.TwoPhaseFlowPipe.Q[4],EconomiseurHP4.TwoPhaseFlowPipe.h[2],EconomiseurHP4.TwoPhaseFlowPipe.h[3],EconomiseurHP4.TwoPhaseFlowPipe.h[4],SurchauffeurHP1.ExchangerWall.Tp[1],SurchauffeurHP1.ExchangerWall.Tp[2],SurchauffeurHP1.ExchangerWall.Tp[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[2],SurchauffeurHP1.TwoPhaseFlowPipe.P[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[4],SurchauffeurHP1.TwoPhaseFlowPipe.Q[1],SurchauffeurHP1.TwoPhaseFlowPipe.Q[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[2],SurchauffeurHP1.TwoPhaseFlowPipe.h[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[4],EconomiseurHP3.ExchangerWall.Tp[1],EconomiseurHP3.ExchangerWall.Tp[2],EconomiseurHP3.ExchangerWall.Tp[3],EconomiseurHP3.TwoPhaseFlowPipe.P[2],EconomiseurHP3.TwoPhaseFlowPipe.P[3],EconomiseurHP3.TwoPhaseFlowPipe.P[4],EconomiseurHP3.TwoPhaseFlowPipe.Q[1],EconomiseurHP3.TwoPhaseFlowPipe.Q[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[3],EconomiseurHP3.TwoPhaseFlowPipe.Q[4],EconomiseurHP3.TwoPhaseFlowPipe.h[2],EconomiseurHP3.TwoPhaseFlowPipe.h[3],EconomiseurHP3.TwoPhaseFlowPipe.h[4],EconomiseurHP2.ExchangerWall.Tp[1],EconomiseurHP2.ExchangerWall.Tp[2],EconomiseurHP2.ExchangerWall.Tp[3],EconomiseurHP2.TwoPhaseFlowPipe.P[2],EconomiseurHP2.TwoPhaseFlowPipe.P[3],EconomiseurHP2.TwoPhaseFlowPipe.P[4],EconomiseurHP2.TwoPhaseFlowPipe.Q[1],EconomiseurHP2.TwoPhaseFlowPipe.Q[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[3],EconomiseurHP2.TwoPhaseFlowPipe.Q[4],EconomiseurHP2.TwoPhaseFlowPipe.h[2],EconomiseurHP2.TwoPhaseFlowPipe.h[3],EconomiseurHP2.TwoPhaseFlowPipe.h[4],EconomiseurHP1.ExchangerWall.Tp[1],EconomiseurHP1.ExchangerWall.Tp[2],EconomiseurHP1.ExchangerWall.Tp[3],EconomiseurHP1.TwoPhaseFlowPipe.P[2],EconomiseurHP1.TwoPhaseFlowPipe.P[3],EconomiseurHP1.TwoPhaseFlowPipe.P[4],EconomiseurHP1.TwoPhaseFlowPipe.Q[1],EconomiseurHP1.TwoPhaseFlowPipe.Q[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[3],EconomiseurHP1.TwoPhaseFlowPipe.Q[4],EconomiseurHP1.TwoPhaseFlowPipe.h[2],EconomiseurHP1.TwoPhaseFlowPipe.h[3],EconomiseurHP1.TwoPhaseFlowPipe.h[4],SurchauffeurHP2.ExchangerWall.Tp[1],SurchauffeurHP2.ExchangerWall.Tp[2],SurchauffeurHP2.ExchangerWall.Tp[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[2],SurchauffeurHP2.TwoPhaseFlowPipe.P[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[4],SurchauffeurHP2.TwoPhaseFlowPipe.Q[1],SurchauffeurHP2.TwoPhaseFlowPipe.Q[2],SurchauffeurHP2.TwoPhaseFlowPipe.Q[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[2],SurchauffeurHP2.TwoPhaseFlowPipe.h[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[4],SurchauffeurHP3.ExchangerWall.Tp[1],SurchauffeurHP3.ExchangerWall.Tp[2],SurchauffeurHP3.ExchangerWall.Tp[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[2],SurchauffeurHP3.TwoPhaseFlowPipe.P[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[4],SurchauffeurHP3.TwoPhaseFlowPipe.Q[1],SurchauffeurHP3.TwoPhaseFlowPipe.Q[2],SurchauffeurHP3.TwoPhaseFlowPipe.Q[3],SurchauffeurHP3.TwoPhaseFlowPipe.Q[4],SurchauffeurHP3.TwoPhaseFlowPipe.h[2],SurchauffeurHP3.TwoPhaseFlowPipe.h[3],SurchauffeurHP3.TwoPhaseFlowPipe.h[4],BallonMP.P,BallonMP.hl,BallonMP.hv,BallonMP.Tp,BallonMP.Vv,EvaporateurMP.ExchangerWall.Tp[1],EvaporateurMP.ExchangerWall.Tp[2],EvaporateurMP.ExchangerWall.Tp[3],EvaporateurMP.TwoPhaseFlowPipe.P[2],EvaporateurMP.TwoPhaseFlowPipe.P[3],EvaporateurMP.TwoPhaseFlowPipe.P[4],EvaporateurMP.TwoPhaseFlowPipe.Q[1],EvaporateurMP.TwoPhaseFlowPipe.Q[2],EvaporateurMP.TwoPhaseFlowPipe.Q[3],EvaporateurMP.TwoPhaseFlowPipe.Q[4],EvaporateurMP.TwoPhaseFlowPipe.h[2],EvaporateurMP.TwoPhaseFlowPipe.h[3],EvaporateurMP.TwoPhaseFlowPipe.h[4],VolumeEvapMP.h,EconomiseurMP.ExchangerWall.Tp[1],EconomiseurMP.ExchangerWall.Tp[2],EconomiseurMP.ExchangerWall.Tp[3],EconomiseurMP.TwoPhaseFlowPipe.P[2],EconomiseurMP.TwoPhaseFlowPipe.P[3],EconomiseurMP.TwoPhaseFlowPipe.P[4],EconomiseurMP.TwoPhaseFlowPipe.Q[1],EconomiseurMP.TwoPhaseFlowPipe.Q[2],EconomiseurMP.TwoPhaseFlowPipe.Q[3],EconomiseurMP.TwoPhaseFlowPipe.Q[4],EconomiseurMP.TwoPhaseFlowPipe.h[2],EconomiseurMP.TwoPhaseFlowPipe.h[3],EconomiseurMP.TwoPhaseFlowPipe.h[4],SurchauffeurMP1.ExchangerWall.Tp[1],SurchauffeurMP1.ExchangerWall.Tp[2],SurchauffeurMP1.ExchangerWall.Tp[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[2],SurchauffeurMP1.TwoPhaseFlowPipe.P[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[4],SurchauffeurMP1.TwoPhaseFlowPipe.Q[1],SurchauffeurMP1.TwoPhaseFlowPipe.Q[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[3],SurchauffeurMP1.TwoPhaseFlowPipe.Q[4],SurchauffeurMP1.TwoPhaseFlowPipe.h[2],SurchauffeurMP1.TwoPhaseFlowPipe.h[3],SurchauffeurMP1.TwoPhaseFlowPipe.h[4],MelangeurHPMP.h,SurchauffeurMP2.ExchangerWall.Tp[1],SurchauffeurMP2.ExchangerWall.Tp[2],SurchauffeurMP2.ExchangerWall.Tp[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[2],SurchauffeurMP2.TwoPhaseFlowPipe.P[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[4],SurchauffeurMP2.TwoPhaseFlowPipe.Q[1],SurchauffeurMP2.TwoPhaseFlowPipe.Q[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[2],SurchauffeurMP2.TwoPhaseFlowPipe.h[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[4],SurchauffeurMP3.ExchangerWall.Tp[1],SurchauffeurMP3.ExchangerWall.Tp[2],SurchauffeurMP3.ExchangerWall.Tp[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[2],SurchauffeurMP3.TwoPhaseFlowPipe.P[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[4],SurchauffeurMP3.TwoPhaseFlowPipe.Q[1],SurchauffeurMP3.TwoPhaseFlowPipe.Q[2],SurchauffeurMP3.TwoPhaseFlowPipe.Q[3],SurchauffeurMP3.TwoPhaseFlowPipe.Q[4],SurchauffeurMP3.TwoPhaseFlowPipe.h[2],SurchauffeurMP3.TwoPhaseFlowPipe.h[3],SurchauffeurMP3.TwoPhaseFlowPipe.h[4],BallonBP.P,BallonBP.hl,BallonBP.hv,BallonBP.Tp,BallonBP.Vv,VolumeEvapBP.h,EvaporateurBP.ExchangerWall.Tp[1],EvaporateurBP.ExchangerWall.Tp[2],EvaporateurBP.ExchangerWall.Tp[3],EvaporateurBP.TwoPhaseFlowPipe.P[2],EvaporateurBP.TwoPhaseFlowPipe.P[3],EvaporateurBP.TwoPhaseFlowPipe.P[4],EvaporateurBP.TwoPhaseFlowPipe.Q[1],EvaporateurBP.TwoPhaseFlowPipe.Q[2],EvaporateurBP.TwoPhaseFlowPipe.Q[3],EvaporateurBP.TwoPhaseFlowPipe.Q[4],EvaporateurBP.TwoPhaseFlowPipe.h[2],EvaporateurBP.TwoPhaseFlowPipe.h[3],EvaporateurBP.TwoPhaseFlowPipe.h[4],SurchauffeurBP.ExchangerWall.Tp[1],SurchauffeurBP.ExchangerWall.Tp[2],SurchauffeurBP.ExchangerWall.Tp[3],SurchauffeurBP.TwoPhaseFlowPipe.P[2],SurchauffeurBP.TwoPhaseFlowPipe.P[3],SurchauffeurBP.TwoPhaseFlowPipe.P[4],SurchauffeurBP.TwoPhaseFlowPipe.Q[1],SurchauffeurBP.TwoPhaseFlowPipe.Q[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[3],SurchauffeurBP.TwoPhaseFlowPipe.Q[4],SurchauffeurBP.TwoPhaseFlowPipe.h[2],SurchauffeurBP.TwoPhaseFlowPipe.h[3],SurchauffeurBP.TwoPhaseFlowPipe.h[4],EconomiseurBP.ExchangerWall.Tp[1],EconomiseurBP.ExchangerWall.Tp[2],EconomiseurBP.ExchangerWall.Tp[3],EconomiseurBP.TwoPhaseFlowPipe.P[2],EconomiseurBP.TwoPhaseFlowPipe.P[3],EconomiseurBP.TwoPhaseFlowPipe.P[4],EconomiseurBP.TwoPhaseFlowPipe.Q[1],EconomiseurBP.TwoPhaseFlowPipe.Q[2],EconomiseurBP.TwoPhaseFlowPipe.Q[3],EconomiseurBP.TwoPhaseFlowPipe.Q[4],EconomiseurBP.TwoPhaseFlowPipe.h[2],EconomiseurBP.TwoPhaseFlowPipe.h[3],EconomiseurBP.TwoPhaseFlowPipe.h[4],MelangeurPostTMP1.h,Condenseur.P,Condenseur.hl,Condenseur.hv,Condenseur.Vv,VolumeCond1.h,VolumeAlimMPHP.h,regulation_Niveau_HP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_3.x,VolumeECO_HP1_2.P,VolumeECO_HP1_2.h,VolumeECO_HP2_3.P,VolumeECO_HP2_3.h,VolumePreTHP.P,VolumePreTHP.h,MelangeurPreTMP.P,MelangeurPreTMP.h) * Number of discrete variables: 9 ($whenCondition1,regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (4826): * Single equations (assignments): 4368 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 276 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 170 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 4 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 1 system {1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 69 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,2,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 101 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,2), (1,2), (1,5), (1,2), (1,2), (1,3), (1,5), (3,16), (1,5), (1,3), (6,14), (1,3), (6,14), (1,3), (1,3), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (1,4), (1,4), (1,4), (1,5), (1,3), (8,15), (1,3)} Notification: Performance of Backend phase and start with SimCode phase: time 0.02596/19.95, allocations: 4.679 MB / 6.579 GB, free: 175.7 MB / 0.9829 GB Notification: Performance of simCode: created initialization part: time 8.761/28.71, allocations: 1.911 GB / 8.489 GB, free: 350.6 MB / 0.9829 GB Notification: Performance of simCode: created event and clocks part: time 2.826e-05/28.71, allocations: 4.656 kB / 8.489 GB, free: 350.6 MB / 0.9829 GB Notification: Performance of simCode: created simulation system equations: time 0.2239/28.93, allocations: 85.23 MB / 8.573 GB, free: 319.2 MB / 0.9829 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.1298/29.06, allocations: 15.57 MB / 8.588 GB, free: 315.3 MB / 0.9829 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.4915/29.55, allocations: 179.9 MB / 8.764 GB, free: 169.7 MB / 0.9829 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.06058/29.61, allocations: 23.43 MB / 8.786 GB, free: 146.2 MB / 0.9829 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.0265/29.64, allocations: 3.087 MB / 8.789 GB, free: 143.1 MB / 0.9829 GB Notification: Performance of SimCode: time 1.022e-06/29.64, allocations: 0 / 8.789 GB, free: 143.1 MB / 0.9829 GB Notification: Performance of Templates: time 38.02/67.66, allocations: 17.56 GB / 26.35 GB, free: 226.5 MB / 0.9985 GB make -j1 -f ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile make -j1 -f ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile clang++ -std=c++14 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/include/omc/sundials" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.o OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.cpp In file included from OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.cpp:25: In file included from ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgLoopMain.cpp:273: ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:93:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp2078.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:94:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp2078.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:95:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp2078.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:96:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp2078.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:97:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp2078.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:98:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_pt_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_pt_ = get<0>(tmp2078.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:99:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cv_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cv_ = get<0>(tmp2078.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:100:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_P_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_P_ = get<1>(tmp2078.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:101:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_T_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_T_ = get<1>(tmp2078.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:102:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_rho_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_rho_ = get<1>(tmp2078.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:103:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_h_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_h_ = get<1>(tmp2078.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:104:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cp_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cp_ = get<1>(tmp2078.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:105:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_pt_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_pt_ = get<1>(tmp2078.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:106:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cv_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cv_ = get<1>(tmp2078.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:112:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp2079.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:113:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp2079.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:114:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp2079.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:115:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp2079.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop10346.cpp:116:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp2079.data).cp_; ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. make: *** [: OMCppThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.o] Error 1