Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo", uses=false) Using package Buildings with version 12.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|TBorFieIn.1..T|TBorFieOut.1..T|TOut.y.1.|TBorFieOut.2..T|TOut.y.2.",fileNamePrefix="Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100") translateModel(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|TBorFieIn.1..T|TBorFieOut.1..T|TOut.y.1.|TBorFieOut.2..T|TOut.y.2.",fileNamePrefix="Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001914/0.001914, allocations: 104.7 kB / 15.98 MB, free: 6.344 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.002203/0.002204, allocations: 196.1 kB / 16.91 MB, free: 6.184 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.435/1.435, allocations: 222.9 MB / 240.6 MB, free: 15.45 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo): time 2.778/2.778, allocations: 482.2 MB / 0.7548 GB, free: 7.359 MB / 0.6231 GB Notification: Performance of FrontEnd - loaded program: time 0.001939/0.001939, allocations: 72.73 kB / 0.9238 GB, free: 0.543 MB / 0.6856 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9401/0.942, allocations: 162.2 MB / 1.082 GB, free: 1.75 MB / 0.8262 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100): time 0.1134/1.055, allocations: 96.91 MB / 1.177 GB, free: 9.742 MB / 0.9044 GB Notification: Performance of NFInst.instExpressions: time 0.05241/1.108, allocations: 32.05 MB / 1.208 GB, free: 14.11 MB / 0.9356 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.008201/1.116, allocations: 127.2 kB / 1.208 GB, free: 13.98 MB / 0.9356 GB Notification: Performance of NFTyping.typeComponents: time 0.008831/1.125, allocations: 2.503 MB / 1.211 GB, free: 11.47 MB / 0.9356 GB Notification: Performance of NFTyping.typeBindings: time 0.01706/1.142, allocations: 4.574 MB / 1.215 GB, free: 6.879 MB / 0.9356 GB Notification: Performance of NFTyping.typeClassSections: time 0.01528/1.157, allocations: 5.064 MB / 1.22 GB, free: 1.859 MB / 0.9356 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFExpression.mo:1586:7-1587:100:writable] Error: Internal error NFExpression.makeSubscriptedExp: too few dimensions in Buildings.Fluid.Geothermal.Borefields.Data.Configuration.Template(Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel, false, 0.0, {0.2304597222222222, 0.2304597222222222}[], {5.531033333333334, 0.921838888888889}[], {34000.0, 34000.0}[], 85.0, 0.075, 0.5, {24, 4}[], {{3.0, 1.5}, {6.0, 1.5}, {9.0, 1.5}, {12.0, 1.5}, {1.5, 4.5}, {4.5, 4.5}, {7.5, 4.5}, {10.5, 4.5}, {3.0, 7.5}, {6.0, 7.5}, {9.0, 7.5}, {12.0, 7.5}, {1.5, 10.5}, {4.5, 10.5}, {7.5, 10.5}, {10.5, 10.5}, {3.0, 13.5}, {6.0, 13.5}, {9.0, 13.5}, {12.0, 13.5}, {1.5, 16.5}, {4.5, 16.5}, {7.5, 16.5}, {10.5, 16.5}, {5.4, 22.5}, {10.8, 22.5}, {2.7, 28.5}, {8.1, 28.5}}, 0.016, 0.42, 0.0029, 0.0282842712474619, {2.304597222222223e-05, 2.304597222222223e-05}[]) to apply subscripts [] [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1731:9-1732:93:writable] Error: Internal error NFCeval.evalRelationEqual failed to evaluate ‘borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1494:9-1494:67:writable] Error: Internal error NFCeval.evalLogicBinaryAnd failed to evaluate ‘true and borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ Notification: Performance of FrontEnd: time 0.01158/1.169, allocations: 7.423 MB / 1.227 GB, free: 10.42 MB / 0.9512 GB