startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | info | The following assertion has been violated at time 232.944368 | | | | DynamicCentrifugalPump1.hn >= 0.0 assert | info | Variable violating min constraint: 0.0 <= DynamicCentrifugalPump1.hn, has value: -4.09765e-15 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00286342s reading init.xml | | | | | | 0.000264907s reading info.xml | | | | | | 6.6274e-05s [ 0.0%] pre-initialization | | | | | | 0.00413731s [ 0.1%] initialization | | | | | | 0.000779412s [ 0.0%] steps | | | | | | 0.00586158s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.62295s [ 48.8%] event-handling | | | | | | 0.0191172s [ 0.6%] overhead | | | | | | 1.67564s [ 50.3%] simulation | | | | | | 3.32855s [100.0%] total | | | | | events | | | | | | 19 state events | | | | | | 3 time events | | | | | solver: dassl | | | | | | 1341 steps taken | | | | | | 1816 calls of functionODE | | | | | | 414 evaluations of jacobian | | | | | | 46 error test failures | | | | | | 0 convergence test failures | | | | | | 0.407229s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.