Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10") translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8011/0.8011, allocations: 150.9 MB / 166 MB, free: 14.54 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0003164/0.0003164, allocations: 19.97 kB / 204 MB, free: 10.06 MB / 174.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1579/0.1582, allocations: 31.33 MB / 235.3 MB, free: 5.559 MB / 190.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10): time 1.566/1.724, allocations: 294.2 MB / 0.5171 GB, free: 12.43 MB / 414.1 MB Notification: Performance of NFInst.instExpressions: time 0.04426/1.768, allocations: 38.43 MB / 0.5547 GB, free: 6.133 MB / 446.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0002949/1.769, allocations: 4 kB / 0.5547 GB, free: 6.129 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:118:3-120:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:121:3-123:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:127:3-131:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.000445/1.769, allocations: 124 kB / 0.5548 GB, free: 6.008 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert. Notification: Performance of FrontEnd: time 8.308e-05/1.769, allocations: 41.83 kB / 0.5548 GB, free: 5.965 MB / 446.1 MB