Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.008 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Thermal.HeatExchanger.ScaledExperiments.CounterCurrentHeatExchangerEquations_N_1280 -s=ida -abortSlowSimulation -alarm=300 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.114046s reading init.xml | | | | | | 0.00990892s reading info.xml | | | | | | 0.00150259s [ 0.1%] pre-initialization | | | | | | 0.00107531s [ 0.0%] initialization | | | | | | 0.000214282s [ 0.0%] steps | | | | | | 0.836426s [ 29.1%] solver (excl. callbacks) | | | | | | 0.0934881s [ 3.3%] creating output-file | | | | | | 0.00138417s [ 0.0%] event-handling | | | | | | 0.00209346s [ 0.1%] overhead | | | | | | 1.93353s [ 67.4%] simulation | | | | | | 2.86972s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 2412 steps taken | | | | | | 2897 calls of functionODE | | | | | | 85 evaluations of jacobian | | | | | | 6 error test failures | | | | | | 0 convergence test failures | | | | | | 0.675522s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.