startTime=0 stopTime=10 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.004 Regular simulation: ./OpenHydraulics_OpenHydraulics.DevelopmentTests.DoubleActingCylinderTestSimple2 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. stdout | info | | | | | WARNING: CylinderChamber has reached end of travel. stdout | info | This could cause erratic behavior of the simulation. stdout | info | (time = 3.84673) assert | info | The following assertion has been violated at time 3.846735 | | | | doubleActingCylinder.cushionRod.s_rel >= 0.0 assert | info | Variable violating min constraint: 0.0 <= doubleActingCylinder.cushionRod.s_rel, has value: -1.00006e-12 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00979484s reading init.xml | | | | | | 0.00158521s reading info.xml | | | | | | 0.000115887s [ 0.2%] pre-initialization | | | | | | 0.000231365s [ 0.5%] initialization | | | | | | 3.176e-06s [ 0.0%] steps | | | | | | 0.00854983s [ 17.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0117283s [ 24.2%] event-handling | | | | | | 0.00197578s [ 4.1%] overhead | | | | | | 0.0259181s [ 53.4%] simulation | | | | | | 0.0485225s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 6211 steps taken | | | | | | 9444 calls of functionODE | | | | | | 786 evaluations of jacobian | | | | | | 236 error test failures | | | | | | 80 convergence test failures | | | | | | 0.00614846s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.