Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.0002 Regular simulation: ./Modelica_3.1_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.DiodeCenterTap2mPulse -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00469095s reading init.xml | | | | | | 0.000397616s reading info.xml | | | | | | 7.989e-05s [ 0.0%] pre-initialization | | | | | | 0.00145391s [ 0.2%] initialization | | | | | | 0.0265739s [ 3.7%] steps | | | | | | 0.00191034s [ 0.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.405783s [ 57.2%] event-handling | | | | | | 0.000388888s [ 0.1%] overhead | | | | | | 0.272711s [ 38.5%] simulation | | | | | | 0.7089s [100.0%] total | | | | | events | | | | | | 61 state events | | | | | | 30 time events | | | | | solver: dassl | | | | | | 2200 steps taken | | | | | | 2650 calls of functionODE | | | | | | 998 evaluations of jacobian | | | | | | 60 error test failures | | | | | | 0 convergence test failures | | | | | | 0.124868s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.