Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus") translateModel(Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001144/0.001145, allocations: 111.3 kB / 15.23 MB, free: 0.6602 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001352/0.001352, allocations: 192.1 kB / 16.13 MB, free: 6.711 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.401/1.401, allocations: 205.1 MB / 222 MB, free: 4.766 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.518/1.518, allocations: 251.7 MB / 0.5088 GB, free: 3.352 MB / 414.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002141/0.002141, allocations: 59.92 kB / 0.6216 GB, free: 2.012 MB / 0.5137 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5588/0.561, allocations: 104.7 MB / 0.7238 GB, free: 13.18 MB / 0.545 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/HeatPumps/Data/EquationFitReversible/Generic.mo:21:3-51:25:writable] Error: Protected sections are not allowed in record. Notification: Performance of FrontEnd: time 0.002688/0.5637, allocations: 1.559 MB / 0.7253 GB, free: 11.61 MB / 0.545 GB