Environment - simulationEnvironment: startTime=1.08e+07 stopTime=1.1232e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ZoneSurface.OneZoneControlledFloorTemperature -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.10.05 10:59 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/21/2017 Continuing Simulation at 01/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/10/2017 Continuing Simulation at 02/10/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/02/2017 Continuing Simulation at 03/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/22/2017 Continuing Simulation at 03/22/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/11/2017 Continuing Simulation at 04/11/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/01/2017 Continuing Simulation at 05/01/2017 for SPAWN-RUNPERIOD assert | warning | The following assertion has been violated at time 10800000.000000 | | | | duc.m_flow >= 0.0 and duc.m_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= duc.m_flow <= 100000.0, has value: -2.63739e-14 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0156261s reading init.xml | | | | | | 0.00132424s reading info.xml | | | | | | 0.000371246s [ 0.0%] pre-initialization | | | | | | 10.547s [ 97.6%] initialization | | | | | | 6.573e-06s [ 0.0%] steps | | | | | | 0.0104076s [ 0.1%] solver (excl. callbacks) | | | | | | 0.00318593s [ 0.0%] creating output-file | | | | | | 0.186918s [ 1.7%] event-handling | | | | | | 0.00997009s [ 0.1%] overhead | | | | | | 0.052069s [ 0.5%] simulation | | | | | | 10.81s [100.0%] total | | | | | events | | | | | | 360 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 7812 steps taken | | | | | | 10033 calls of functionODE | | | | | | 4493 evaluations of jacobian | | | | | | 153 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0147113s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 2.81sec EnergyPlus Completed Successfully.