Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./Buildings_10_Buildings.Fluid.Movers.Validation.FlowControlled_m_flow -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | floMacSta.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in FlowControlled_m_flow.floMacSta: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (floMacSta.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or floMacSta.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in FlowControlled_m_flow.floMacSta: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | floMacSta.per.haveWMot_nominal or not (floMacSta.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or floMacSta.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in FlowControlled_m_flow.floMacSta: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | floMacDyn.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in FlowControlled_m_flow.floMacDyn: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (floMacDyn.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or floMacDyn.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in FlowControlled_m_flow.floMacDyn: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | floMacDyn.per.haveWMot_nominal or not (floMacDyn.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or floMacDyn.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in FlowControlled_m_flow.floMacDyn: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.013671s reading init.xml | | | | | | 0.00131272s reading info.xml | | | | | | 0.000769133s [ 3.8%] pre-initialization | | | | | | 0.000547116s [ 2.7%] initialization | | | | | | 1.803e-06s [ 0.0%] steps | | | | | | 0.000744337s [ 3.7%] solver (excl. callbacks) | | | | | | 0.00165933s [ 8.3%] creating output-file | | | | | | 0.000244149s [ 1.2%] event-handling | | | | | | 0.00469829s [ 23.4%] overhead | | | | | | 0.011373s [ 56.8%] simulation | | | | | | 0.0200372s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 115 steps taken | | | | | | 169 calls of functionODE | | | | | | 59 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 1 convergence test failures | | | | | | 0.000118023s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.