Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./Buildings_10_Buildings.Fluid.Movers.Examples.MoverParameter -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump_m_flow.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in MoverParameter.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pump_m_flow.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_m_flow.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in MoverParameter.pump_m_flow: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump_m_flow.per.haveWMot_nominal or not (pump_m_flow.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump_m_flow.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in MoverParameter.pump_m_flow: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0201115s reading init.xml | | | | | | 0.00189903s reading info.xml | | | | | | 0.00110766s [ 3.0%] pre-initialization | | | | | | 0.0011315s [ 3.1%] initialization | | | | | | 3.396e-06s [ 0.0%] steps | | | | | | 6.351e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00229947s [ 6.2%] creating output-file | | | | | | -5.16161e-21s [ -0.0%] event-handling | | | | | | 0.00903321s [ 24.5%] overhead | | | | | | 0.0232613s [ 63.1%] simulation | | | | | | 0.0369236s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 5000 steps taken | | | | | | 5000 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.