Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_10_Buildings.Fluid.HeatExchangers.Examples.AirHeater_u -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in AirHeater_u.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in AirHeater_u.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0133735s reading init.xml | | | | | | 0.00102625s reading info.xml | | | | | | 0.000590116s [ 1.6%] pre-initialization | | | | | | 0.000355797s [ 0.9%] initialization | | | | | | 3.136e-06s [ 0.0%] steps | | | | | | 0.00455072s [ 12.0%] solver (excl. callbacks) | | | | | | 0.00207818s [ 5.5%] creating output-file | | | | | | 0.00100695s [ 2.6%] event-handling | | | | | | 0.00728715s [ 19.2%] overhead | | | | | | 0.0221763s [ 58.3%] simulation | | | | | | 0.0380484s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2037 steps taken | | | | | | 2897 calls of functionODE | | | | | | 327 evaluations of jacobian | | | | | | 124 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00305001s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.