Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Cooling.Examples.Indirect -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pumBui.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumBui.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Indirect.pumBui: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumBui.per.haveWMot_nominal or not (pumBui.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumBui.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Indirect.pumBui: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0148473s reading init.xml | | | | | | 0.00144084s reading info.xml | | | | | | 0.000658585s [ 1.1%] pre-initialization | | | | | | 0.000459011s [ 0.8%] initialization | | | | | | 4.839e-06s [ 0.0%] steps | | | | | | 0.00242959s [ 4.2%] solver (excl. callbacks) | | | | | | 0.00260834s [ 4.5%] creating output-file | | | | | | 0.000420686s [ 0.7%] event-handling | | | | | | 0.0129113s [ 22.3%] overhead | | | | | | 0.0384923s [ 66.4%] simulation | | | | | | 0.0579846s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1192 steps taken | | | | | | 1744 calls of functionODE | | | | | | 208 evaluations of jacobian | | | | | | 65 error test failures | | | | | | 1 convergence test failures | | | | | | 0.00274888s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.