Environment - simulationEnvironment: startTime=0 stopTime=864000 tolerance=1e-06 numberOfIntervals=240 stepSize=3600 Regular simulation: ./Buildings_10_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36 -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS stdout | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in Guideline36.hvac.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in Guideline36.hvac.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated at time 0.000000 | | | | con.ySupFan >= max(0.0, max(0.0, max(con.conEco.supFanSpe_min, 0.0))) and con.ySupFan <= min(1.0, min(1.0, min(con.conEco.supFanSpe_max, 1.0))) assert | warning | Variable violating min/max constraint: max(0.0, max(0.0, max(con.conEco.supFanSpe_min, 0.0))) <= con.ySupFan <= min(1.0, min(1.0, min(con.conEco.supFanSpe_max, 1.0))), has value: 0 assert | warning | The following assertion has been violated at time 0.000000 | | | | con.outAirSetPoi.VMinOA_flow >= 0.0144 and con.outAirSetPoi.VMinOA_flow <= min(con.conEco.damLim.VOutDes_flow, con.conEco.VOutDes_flow) assert | warning | Variable violating min/max constraint: 0.0144 <= con.outAirSetPoi.VMinOA_flow <= min(con.conEco.damLim.VOutDes_flow, con.conEco.VOutDes_flow), has value: 0 LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: hvac.cooCoi.m1_flow + hvac.ideVal.preMasFlo.m_flow assert | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: hvac.cooCoi.m1_flow + hvac.ideVal.preMasFlo.m_flow assert | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: hvac.cooCoi.m1_flow + hvac.ideVal.preMasFlo.m_flow