Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_1.6_Buildings.Examples.ChillerPlant.DataCenterRenewables -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (dataCenterContinuousTimeControl.fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or dataCenterContinuousTimeControl.fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | dataCenterContinuousTimeControl.fan.per.haveWMot_nominal or not (dataCenterContinuousTimeControl.fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or dataCenterContinuousTimeControl.fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (dataCenterContinuousTimeControl.pumCHW.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or dataCenterContinuousTimeControl.pumCHW.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.pumCHW: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | dataCenterContinuousTimeControl.pumCHW.per.haveWMot_nominal or not (dataCenterContinuousTimeControl.pumCHW.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or dataCenterContinuousTimeControl.pumCHW.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.pumCHW: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (dataCenterContinuousTimeControl.pumCW.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or dataCenterContinuousTimeControl.pumCW.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.pumCW: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | dataCenterContinuousTimeControl.pumCW.per.haveWMot_nominal or not (dataCenterContinuousTimeControl.pumCW.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or dataCenterContinuousTimeControl.pumCW.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.pumCW: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated at time 0.000000 | | | | dataCenterContinuousTimeControl.fan.heaDis.etaHyd >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= dataCenterContinuousTimeControl.fan.heaDis.etaHyd, has value: -4.02209e-05 assert | warning | The following assertion has been violated at time 0.000000 | | | | dataCenterContinuousTimeControl.fan.eff.yMot >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= dataCenterContinuousTimeControl.fan.eff.yMot, has value: -1.61688e-14 assert | warning | The following assertion has been violated at time 0.000000 | | | | dataCenterContinuousTimeControl.cooTow.TAppCor >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= dataCenterContinuousTimeControl.cooTow.TAppCor, has value: -0.615124 LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0763723s reading init.xml | | | | | | 0.00602443s reading info.xml | | | | | | 0.00079941s [ 0.1%] pre-initialization | | | | | | 0.0362256s [ 5.4%] initialization | | | | | | 4.3842e-05s [ 0.0%] steps | | | | | | 0.0385893s [ 5.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.159014s [ 23.6%] event-handling | | | | | | 0.0369479s [ 5.5%] overhead | | | | | | 0.401818s [ 59.7%] simulation | | | | | | 0.673438s [100.0%] total | | | | | events | | | | | | 92 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 6008 steps taken | | | | | | 8682 calls of functionODE | | | | | | 1717 evaluations of jacobian | | | | | | 437 error test failures | | | | | | 0 convergence test failures | | | | | | 0.17393s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.