Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.Examples.SimpleHouse -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in SimpleHouse.pump: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump.per.haveWMot_nominal or not (pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in SimpleHouse.pump: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (fan.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fan.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in SimpleHouse.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | fan.per.haveWMot_nominal or not (fan.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fan.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in SimpleHouse.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0308606s reading init.xml | | | | | | 0.00269553s reading info.xml | | | | | | 0.000194334s [ 0.0%] pre-initialization | | | | | | 0.0330005s [ 1.8%] initialization | | | | | | 0.000504526s [ 0.0%] steps | | | | | | 0.134883s [ 7.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.542397s [ 30.0%] event-handling | | | | | | 0.017851s [ 1.0%] overhead | | | | | | 1.08201s [ 59.8%] simulation | | | | | | 1.81084s [100.0%] total | | | | | events | | | | | | 1012 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 158439 steps taken | | | | | | 200890 calls of functionODE | | | | | | 19928 evaluations of jacobian | | | | | | 4783 error test failures | | | | | | 0 convergence test failures | | | | | | 0.468458s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.