Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust") translateModel(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001098/0.001098, allocations: 111.3 kB / 15.23 MB, free: 0.6602 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001061/0.001061, allocations: 189.3 kB / 16.13 MB, free: 6.652 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.679/1.679, allocations: 205.1 MB / 222 MB, free: 4.742 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.448/0.448, allocations: 54.93 MB / 324.3 MB, free: 148 kB / 254.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Annex60 requested package Modelica of version 3.2.2. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001384/0.001385, allocations: 63.91 kB / 394.7 MB, free: 12.27 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1316/0.133, allocations: 59.58 MB / 454.3 MB, free: 0.6211 MB / 382.1 MB Notification: Performance of NFInst.instantiate(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust): time 1.052/1.185, allocations: 377.6 MB / 0.8124 GB, free: 14.29 MB / 0.5606 GB Notification: Performance of NFInst.instExpressions: time 0.06358/1.249, allocations: 47.46 MB / 0.8587 GB, free: 14.69 MB / 0.6075 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01039/1.259, allocations: 155.1 kB / 0.8589 GB, free: 14.54 MB / 0.6075 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Conversion/AirToOutlet.mo:92:3-94:60:writable] Warning: Connector bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Conversion/InletToAir.mo:76:3-78:60:writable] Warning: Connector bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01146/1.271, allocations: 2.496 MB / 0.8613 GB, free: 12.03 MB / 0.6075 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Adaptors/HVAC.mo:48:16-48:66:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Adaptors/HVAC.mo:47:3-56:28:writable] Error: Type mismatch in binding ‘quantity = fill(hvacAda.Medium.extraPropertiesNames, 3)‘, expected array dimensions [], got [3, 0]. Notification: Performance of FrontEnd: time 0.0001859/1.271, allocations: 43.81 kB / 0.8613 GB, free: 11.99 MB / 0.6075 GB