Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=172 stepSize=502.326 Regular simulation: ./AixLib_latest_AixLib.Fluid.Examples.GeothermalHeatPump.GeothermalHeatPump -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | In GeothermalHeatPump.heatPump.con: The constant homotopyInitialization has been modified from its default value. This constant will be removed in future releases. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | In GeothermalHeatPump.heatPump.eva: The constant homotopyInitialization has been modified from its default value. This constant will be removed in future releases. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumpColdConsumer.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumpHeatConsumer.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumpCondenser.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumpEvaporator.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumpGeothermalSource.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | In GeothermalHeatPump.heatPump.con.preDro: The constant homotopyInitialization has been modified from its default value. This constant will be removed in future releases. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | In GeothermalHeatPump.heatPump.eva.preDro: The constant homotopyInitialization has been modified from its default value. This constant will be removed in future releases. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.122853s reading init.xml | | | | | | 0.0113615s reading info.xml | | | | | | 0.000473568s [ 0.0%] pre-initialization | | | | | | 0.0014859s [ 0.0%] initialization | | | | | | 0.0157522s [ 0.1%] steps | | | | | | 0.974689s [ 8.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.85277s [ 15.7%] event-handling | | | | | | 0.0146729s [ 0.1%] overhead | | | | | | 8.96501s [ 75.8%] simulation | | | | | | 11.8249s [100.0%] total | | | | | events | | | | | | 328 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 37091 steps taken | | | | | | 58538 calls of functionODE | | | | | | 12016 evaluations of jacobian | | | | | | 4202 error test failures | | | | | | 24 convergence test failures | | | | | | 6.69518s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.