OMSimulator --tempDir=temp_StewartPlatform_StewartPlatform_Tests_Leg_test_fmu --startTime=0 --stopTime=10 --timeout=50 --tolerance=1e-06 StewartPlatform_StewartPlatform_Tests_Leg_test.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/StewartPlatform_StewartPlatform.Tests.Leg_test/temp_StewartPlatform_StewartPlatform_Tests_Leg_test_fmu/model-el6x206t/temp/0001_StewartPlatform_StewartPlatform_Tests_Leg_test (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/StewartPlatform 1.0.2/Components/PartialElectricCylinder.mo:47: The following assertion has been violated during initialization at time 0.000000 leg.electricCylinder.electricCylinderParameters.initialLength <= leg.electricCylinder.electricCylinderParameters.maxLength and leg.electricCylinder.electricCylinderParameters.initialLength >= leg.electricCylinder.electricCylinderParameters.minLength assert | warning | PartialElectricCylinder: Initial length is not within [minLength, maxLength] warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/StewartPlatform_StewartPlatform.Tests.Leg_test/temp_StewartPlatform_StewartPlatform_Tests_Leg_test_fmu/model-el6x206t/temp/0001_StewartPlatform_StewartPlatform_Tests_Leg_test (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/StewartPlatform 1.0.2/Components/PartialElectricCylinder.mo:47: The following assertion has been violated during initialization at time 0.000000 leg.electricCylinder.electricCylinderParameters.initialLength <= leg.electricCylinder.electricCylinderParameters.maxLength and leg.electricCylinder.electricCylinderParameters.initialLength >= leg.electricCylinder.electricCylinderParameters.minLength assert | warning | PartialElectricCylinder: Initial length is not within [minLength, maxLength] warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/StewartPlatform_StewartPlatform.Tests.Leg_test/temp_StewartPlatform_StewartPlatform_Tests_Leg_test_fmu/model-el6x206t/temp/0001_StewartPlatform_StewartPlatform_Tests_Leg_test (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/StewartPlatform 1.0.2/Components/PartialElectricCylinder.mo:45: The following assertion has been violated during initialization at time 0.000000 abs(leg.electricCylinder.stroke) <= 0.5 * leg.electricCylinder.electricCylinderParameters.workingStroke assert | warning | PartialElectricCylinder: The current stroke is over the working stroke. info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.StewartPlatform_StewartPlatform_Tests_Leg_test.leg.electricCylinder.bodyBox.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.StewartPlatform_StewartPlatform_Tests_Leg_test.leg.electricCylinder.bodyCylinder.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.StewartPlatform_StewartPlatform_Tests_Leg_test.leg.universalJoint.fixedRotation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.StewartPlatform_StewartPlatform_Tests_Leg_test.world.label1 will not be stored in the result file, because the signal type is not supported info: Parameter model.root.StewartPlatform_StewartPlatform_Tests_Leg_test.world.label2 will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 185077 NumRhsEvals = 301035 NumLinSolvSetups = 104507 NumNonlinSolvIters = 301034 NumNonlinSolvConvFails = 0 NumErrTestFails = 34465 info: 3 warnings info: 0 errors