Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=50 stepSize=0.02 Regular simulation: ./PowerGrids_dev_PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault -abortSlowSimulation -alarm=50 -emit_protected -lv LOG_STATS stdout | info | Using sparse solver for linear system 0, | | | | because density of 0.062 remains under threshold of 0.200. stdout | info | Using sparse solver for linear system 1, | | | | because density of 0.094 remains under threshold of 0.200. stdout | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. stdout | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | info | The following assertion has been violated at time 0.400000 | | | | infiniteBusA.IPuCheck < infiniteBusA.IPuMax assert | info | Current too high (IPu=5.41126 > 2.5), check if the numerical solution is valid assert | info | The following assertion has been violated at time 0.400000 | | | | transmissionLine.threePhaseFault.VPuCheck > transmissionLine.threePhaseFault.VPuMin assert | info | Voltage too low (VPu=0.469697 < 0.7), check if the numerical solution is valid assert | info | The following assertion has been violated at time 0.400000 | | | | transmissionLine.threePhaseFault.IPuCheck < transmissionLine.threePhaseFault.IPuMax assert | info | Current too high (IPu=15.6566 > 2.5), check if the numerical solution is valid assert | info | The following assertion has been violated at time 0.400000 | | | | transmissionLine.busFault.VPuCheck > transmissionLine.busFault.VPuMin assert | info | Voltage too low (VPu=0.469697 < 0.7), check if the numerical solution is valid assert | info | The following assertion has been violated at time 0.400000 | | | | infiniteBusB.IPuCheck < infiniteBusB.IPuMax assert | info | Current too high (IPu=9.22078 > 2.5), check if the numerical solution is valid LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0183344s reading init.xml | | | | | | 0.00209999s reading info.xml | | | | | | 0.00497712s [ 60.3%] pre-initialization | | | | | | 0.000654537s [ 7.9%] initialization | | | | | | 2.956e-06s [ 0.0%] steps | | | | | | 0.00244151s [ 29.6%] solver (excl. callbacks) | | | | | | 0.000427416s [ 5.2%] creating output-file | | | | | | 0.000709379s [ 8.6%] event-handling | | | | | | 0.000183027s [ 2.2%] overhead | | | | | | -0.00114727s [-13.9%] simulation | | | | | | 0.00824868s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 50 steps taken | | | | | | 50 calls of functionODE | | | | | | 44 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000461275s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.