/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables_res.mat --tempDir=temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu --startTime=0 --stopTime=604800 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (dataCenterContinuousTimeControl.fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or dataCenterContinuousTimeControl.fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 dataCenterContinuousTimeControl.fan.per.haveWMot_nominal or not (dataCenterContinuousTimeControl.fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or dataCenterContinuousTimeControl.fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (dataCenterContinuousTimeControl.pumCHW.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or dataCenterContinuousTimeControl.pumCHW.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.pumCHW: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 dataCenterContinuousTimeControl.pumCHW.per.haveWMot_nominal or not (dataCenterContinuousTimeControl.pumCHW.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or dataCenterContinuousTimeControl.pumCHW.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.pumCHW: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (dataCenterContinuousTimeControl.pumCW.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or dataCenterContinuousTimeControl.pumCW.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.pumCW: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 dataCenterContinuousTimeControl.pumCW.per.haveWMot_nominal or not (dataCenterContinuousTimeControl.pumCW.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or dataCenterContinuousTimeControl.pumCW.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in DataCenterRenewables.dataCenterContinuousTimeControl.pumCW: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46: The following assertion has been violated at time 0.000000 dataCenterContinuousTimeControl.fan.heaDis.etaHyd >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= dataCenterContinuousTimeControl.fan.heaDis.etaHyd, has value: -4.02209e-05 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 0.000000 dataCenterContinuousTimeControl.fan.eff.yMot >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= dataCenterContinuousTimeControl.fan.eff.yMot, has value: -1.61688e-14 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables/temp_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables_fmu/model-u9pygdbi/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/HeatExchangers/CoolingTowers/YorkCalc.mo:44: The following assertion has been violated at time 0.000000 dataCenterContinuousTimeControl.cooTow.TAppCor >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= dataCenterContinuousTimeControl.cooTow.TAppCor, has value: -0.615124 info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_latest_Buildings.Examples.ChillerPlant.DataCenterRenewables_res.mat (bufferSize=1) info: Parameter model.root.Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables.winTur.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_Examples_ChillerPlant_DataCenterRenewables.winTur.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 9 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 164347 NumRhsEvals = 164363 NumLinSolvSetups = 8219 NumNonlinSolvIters = 164362 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21