/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain_res.mat --tempDir=temp_Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_fmu --startTime=0 --stopTime=604800 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain/temp_Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_fmu/model-4g7fly2t/temp/0001_Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28: The following assertion has been violated during initialization at time 0.000000 not senRelHum.warnAboutOnePortConnection assert | warning | Sensor RoomWithoutLatentGain.senRelHum can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithoutLatentGain.senRelHum. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain/temp_Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_fmu/model-4g7fly2t/temp/0001_Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28: The following assertion has been violated during initialization at time 0.000000 not senMasFra.warnAboutOnePortConnection assert | warning | Sensor RoomWithoutLatentGain.senMasFra can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithoutLatentGain.senMasFra. info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_9_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain_res.mat (bufferSize=1) info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.assEqu.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.intGai.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.intGai.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.outdoorTemp.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.outdoorTemp.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.reference.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.reference.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.senMasFra.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.tableSolRadWindow.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.tableSolRadWindow.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.ventRate.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.ventRate.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain/temp_Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_fmu/model-4g7fly2t/temp/0001_Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.Buildings_9_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain"