OMSimulator --tempDir=temp_Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8_fmu --startTime=0 --stopTime=5.184e+06 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.assEqu.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.intGai.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.intGai.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.outdoorTemp1.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.outdoorTemp1.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.reference.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.reference.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.tableSolRadWall.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.tableSolRadWall.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.tableSolRadWindow.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase8.tableSolRadWindow.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 1212580 NumRhsEvals = 1212581 NumLinSolvSetups = 60630 NumNonlinSolvIters = 1212580 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21