OMSimulator --tempDir=temp_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly_fmu --startTime=0 --stopTime=360000 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Generation5.Validation.ChillerOnly/temp_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly_fmu/model-r3c14b6v/temp/0001_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30: The following assertion has been violated at time 0.000000 ets.hex.m2_flow >= 0.0 and ets.hex.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ets.hex.m2_flow <= 100000.0, has value: -5.61766e-20 info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly.TDisWatSup.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly.TDisWatSup.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly.loa.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly.loa.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 1 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Generation5.Validation.ChillerOnly/temp_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly_fmu/model-r3c14b6v/temp/0001_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [updateInputs] fmi2_setTime failed for FMU "model.root.Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Validation_ChillerOnly" malloc_consolidate(): unaligned fastbin chunk detected