/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.YorkCalc_res.mat --tempDir=temp_Buildings_10_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc_fmu --startTime=1.5552e+07 --stopTime=1.57248e+07 --timeout=50 --tolerance=1e-06 Buildings_10_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.YorkCalc/temp_Buildings_10_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc_fmu/model-yjdneu3n/temp/0001_Buildings_10_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in YorkCalc.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.YorkCalc/temp_Buildings_10_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc_fmu/model-yjdneu3n/temp/0001_Buildings_10_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in YorkCalc.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.YorkCalc/temp_Buildings_10_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc_fmu/model-yjdneu3n/temp/0001_Buildings_10_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/HeatExchangers/CoolingTowers/YorkCalc.mo:44: The following assertion has been violated at time 0.000000 tow.TAppCor >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= tow.TAppCor, has value: -0.615124 info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_10_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.YorkCalc_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 3 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 663856 NumRhsEvals = 663857 NumLinSolvSetups = 33194 NumNonlinSolvIters = 663856 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21