Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_10_Buildings.Examples.DualFanDualDuct.ClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/package.mo", uses=false) Using package Buildings with version 10.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.Examples.DualFanDualDuct.ClosedLoop,fileNamePrefix="Buildings_10_Buildings_Examples_DualFanDualDuct_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Examples.DualFanDualDuct.ClosedLoop,fileNamePrefix="Buildings_10_Buildings_Examples_DualFanDualDuct_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) Thread is still alive. OMC died, but the thread is still running? This will end badly. The log-file of omc: Created ZeroMQ Server. Dumped server port in file: /tmp/openmodelica.hudson.port.4e374e3a4d2448fa8eb5509453f9e4b9 Nonlinear iteration variables with predefined start attribute in NLSJac4. (1) ======================================== 1: weaBus.TWetBul:VARIABLE(flow=false min = max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, 0.0)))))))))))))))))))))))))))))))))))))) start = 288.15 unit = "K" nominal = 300.0 ) "Wet bulb temperature" type: Real Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") Nonlinear iteration variables with predefined start attribute in NLSJac36. (1) ======================================== 1: cooCoi.UAFroRated.UAWat:VARIABLE(min = 0.0 start = 20.0 unit = "W/K" fixed = false protected = true ) "Water side convective heat transfer coefficient" type: Real Linear iteration variables with predefined start attributes that are unrelevant in NLSJac36. (1) ======================================== 1: cooCoi.UAFroRated.UAAir:VARIABLE(min = 0.0 start = 10.0 unit = "W/K" fixed = false protected = true ) "Air side convective heat transfer coefficient, including fin resistance" type: Real Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") Nonlinear iteration variables with predefined start attribute in NLSJac41. (1) ======================================== 1: weaBus.TWetBul:VARIABLE(flow=false min = max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, max(0.0, 0.0)))))))))))))))))))))))))))))))))))))) start = 288.15 unit = "K" nominal = 300.0 ) "Wet bulb temperature" type: Real Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") Nonlinear iteration variables with predefined start attribute in NLSJac68. (1) ======================================== 1: cooCoi.UAFroRated.UAWat:VARIABLE(min = 0.0 start = 20.0 unit = "W/K" fixed = false protected = true ) "Water side convective heat transfer coefficient" type: Real Linear iteration variables with predefined start attributes that are unrelevant in NLSJac68. (1) ======================================== 1: cooCoi.UAFroRated.UAAir:VARIABLE(min = 0.0 start = 10.0 unit = "W/K" fixed = false protected = true ) "Air side convective heat transfer coefficient, including fin resistance" type: Real Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") mmap(PROT_NONE) failed Aborted (core dumped) Aborted the command. Failed to read output from testmodel.py, exit status != 0: OMC died, but the thread is still running? This will end badly.