/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Sensors.Examples.TraceSubstances/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances_fmu/model-cb6sgx1y/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Interfaces/PartialTwoPortInterface.mo:19: The following assertion has been violated at time 0.000000 (if res.m_flow_nominal_pos > 1e-15 then res.m_flow_nominal_pos else 1.0) >= -100000.0 and (if res.m_flow_nominal_pos > 1e-15 then res.m_flow_nominal_pos else 1.0) <= 0.0 assert | warning | Nominal variable violating min/max constraint: -100000.0 <= res.m_flow <= 0.0, has value: 0.005 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Sensors.Examples.TraceSubstances/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances_fmu/model-cb6sgx1y/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Interfaces/PartialTwoPortInterface.mo:19: The following assertion has been violated at time 0.000000 res.m_flow >= -100000.0 and res.m_flow <= 0.0 assert | warning | Variable violating min/max constraint: -100000.0 <= res.m_flow <= 0.0, has value: 2.18279e-14 info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances.senPPM.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances.senSou.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances.senTraSub.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances.senTraSubNoFlorRev.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances.senVol.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildSysPro_BuildSysPro_IBPSA_Fluid_Sensors_Examples_TraceSubstances.sou.substanceName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 2318170 NumRhsEvals = 2318171 NumLinSolvSetups = 115910 NumNonlinSolvIters = 2318170 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21