/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu --startTime=0 --stopTime=1 --timeout=50 --tolerance=1e-06 BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.FlowControlled_dp/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-4854r8t4/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387: The following assertion has been violated during initialization at time 0.000000 floMacSta.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.FlowControlled_dp/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-4854r8t4/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420: The following assertion has been violated during initialization at time 0.000000 not (floMacSta.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or floMacSta.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in FlowControlled_dp.floMacSta: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.FlowControlled_dp/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-4854r8t4/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 floMacSta.per.haveWMot_nominal or not (floMacSta.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or floMacSta.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in FlowControlled_dp.floMacSta: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.FlowControlled_dp/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-4854r8t4/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387: The following assertion has been violated during initialization at time 0.000000 floMacDyn.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.FlowControlled_dp/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-4854r8t4/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420: The following assertion has been violated during initialization at time 0.000000 not (floMacDyn.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or floMacDyn.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in FlowControlled_dp.floMacDyn: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.FlowControlled_dp/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-4854r8t4/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 floMacDyn.per.haveWMot_nominal or not (floMacDyn.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or floMacDyn.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in FlowControlled_dp.floMacDyn: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.FlowControlled_dp/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-4854r8t4/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/FlowControlled_dp.mo:100: The following assertion has been violated at time 0.751000 floMacDyn.dpMachine >= -0.001 assert | error | Pressure set point for mover cannot be negative. Obtained dp = -1 error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.FlowControlled_dp/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-4854r8t4/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_FlowControlled_dp (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sou.verifyInputs info: Final Statistics for 'model.root': NumSteps = 257 NumRhsEvals = 262 NumLinSolvSetups = 18 NumNonlinSolvIters = 261 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 7 warnings info: 2 errors