OMSimulator --tempDir=temp_AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump_fmu --startTime=0 --stopTime=20000 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.heatPump.innerCycle.PerformanceDataHPCooling.P_eleTable.combiTable2D.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.heatPump.innerCycle.PerformanceDataHPCooling.P_eleTable.combiTable2D.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.heatPump.innerCycle.PerformanceDataHPCooling.Qdot_EvaTable.combiTable2D.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.heatPump.innerCycle.PerformanceDataHPCooling.Qdot_EvaTable.combiTable2D.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.heatPump.innerCycle.PerformanceDataHPHeating.P_eleTable.combiTable2D.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.heatPump.innerCycle.PerformanceDataHPHeating.P_eleTable.combiTable2D.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.heatPump.innerCycle.PerformanceDataHPHeating.Qdot_ConTable.combiTable2D.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Obsolete_YearIndependent_FastHVAC_Examples_HeatGenerators_HeatPump_HeatPump.heatPump.innerCycle.PerformanceDataHPHeating.Qdot_ConTable.combiTable2D.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors