OMSimulator --tempDir=temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation_fmu --startTime=0 --stopTime=29600 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.fmu stdout | info | ... loading "Boundary" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation/temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation_fmu/model-9kp42gfv/temp/0001_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationEta.txt" stdout | info | ... loading "Boundary" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation/temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation_fmu/model-9kp42gfv/temp/0001_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationOda.txt" stdout | info | ... loading "Result" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation/temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation_fmu/model-9kp42gfv/temp/0001_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationResult.txt" warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation/temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation_fmu/model-9kp42gfv/temp/0001_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 fan.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation/temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation_fmu/model-9kp42gfv/temp/0001_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 fan1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.Results.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.bondaryEta.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.bondaryOda.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.senMasFraEha.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.senMasFraEta.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.senMasFraOda.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.senMasFraSup.substanceName will not be stored in the result file, because the signal type is not supported assert | debug | memory_pool.c: Error: Failed to allocate memory (calloc returned NULL.) error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation/temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation_fmu/model-9kp42gfv/temp/0001_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable souOda.verifyInputs error: [operator()] Timeout occurred during simulation info: 2 warnings info: 3 errors info: Final Statistics for 'model.root': NumSteps = 11522 NumRhsEvals = 11553 NumLinSolvSetups = 594 NumNonlinSolvIters = 11552 NumNonlinSolvConvFails = 0 NumErrTestFails = 4