/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AES_AES_Coursework_ThermSys_control_problems_Temperature_control_pipes_Tcontrol_pipes_sensor_dynamics_02_PI_fmu --startTime=0 --stopTime=100 --timeout=50 --tolerance=1e-06 AES_AES_Coursework_ThermSys_control_problems_Temperature_control_pipes_Tcontrol_pipes_sensor_dynamics_02_PI.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 71294 NumRhsEvals = 71295 NumLinSolvSetups = 3566 NumNonlinSolvIters = 71294 NumNonlinSolvConvFails = 0 NumErrTestFails = 0