Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IDEAS_IDEAS.Examples.Benchmark.ScalingBuildings.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo", uses=false) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IDEAS.Examples.Benchmark.ScalingBuildings,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_IDEAS.Examples.Benchmark.ScalingBuildings") translateModel(IDEAS.Examples.Benchmark.ScalingBuildings,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_IDEAS.Examples.Benchmark.ScalingBuildings") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00573/0.00573, allocations: 100.2 kB / 15.87 MB, free: 5.867 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001091/0.001091, allocations: 189.3 kB / 16.79 MB, free: 5.809 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.326/1.326, allocations: 222.9 MB / 240.5 MB, free: 4.574 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo): time 0.7416/0.7416, allocations: 132.2 MB / 422.8 MB, free: 2.004 MB / 350.1 MB Warning: Ignoring unknown experiment annotation option: __Dymola_fixedstepsize = 30 Warning: Ignoring unknown experiment annotation option: __Dymola_Algorithm = "Dassl" Warning: Ignoring unknown experiment annotation option: __Dymola_fixedstepsize = 30 Warning: Ignoring unknown experiment annotation option: __Dymola_Algorithm = "Dassl" Notification: Performance of FrontEnd - loaded program: time 0.001166/0.001166, allocations: 59.66 kB / 0.5017 GB, free: 4.301 MB / 366.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5071/0.5083, allocations: 80.21 MB / 0.58 GB, free: 4.523 MB / 430.1 MB Notification: Performance of NFInst.instantiate(IDEAS.Examples.Benchmark.ScalingBuildings): time 1.803/2.312, allocations: 0.5971 GB / 1.177 GB, free: 1.621 MB / 0.795 GB Notification: Performance of NFInst.instExpressions: time 0.3505/2.662, allocations: 230.1 MB / 1.402 GB, free: 11.73 MB / 0.8887 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.08064/2.743, allocations: 1.166 MB / 1.403 GB, free: 10.55 MB / 0.8887 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/BoundaryConditions/Interfaces/PartialSimInfoManager.mo:151:3-154:55:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/InterzonalAirFlow/BaseClasses/PartialInterzonalAirFlowBoundary.mo:21:3-22:72:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialZone.mo:195:3-207:27:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Zone.mo:6:3-18:28:writable] Warning: Connector propsBus is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/BoundaryWall.mo:64:3-66:71:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0199/2.763, allocations: 6.244 MB / 1.409 GB, free: 4.98 MB / 0.8887 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Examples/Benchmark/ScalingBuildings.mo:9:3-10:20:writable] Error: Component angleOffsets of variability constant has binding '{2 * i * Modelica.Constants.pi / n for i in 1:n}' of higher variability parameter. Notification: Performance of FrontEnd: time 0.003427/2.766, allocations: 0.5695 MB / 1.41 GB, free: 4.504 MB / 0.8887 GB