Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ClaRa_ClaRa.StaticCycles.Check.TestStacy5.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo", uses=false) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo) Running command: translateModel(ClaRa.StaticCycles.Check.TestStacy5,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="Time|staCy.condenser.outlet.m_flow|staCy.condenser.outlet.p|staCy.condenser.summary.outlet.m_flow|staCy.condenser.summary.outlet.p|staCy.feedwatertank.cond_out.m_flow|staCy.feedwatertank.cond_out.p|staCy.feedwatertank.summary.outlet_cond.m_flow|staCy.feedwatertank.summary.outlet_cond.p|staCy.mixer2.outlet.m_flow|staCy.mixer2.outlet.p|staCy.mixer2.summary.outlet.m_flow|staCy.mixer2.summary.outlet.p|staCy.mixer2_1.outlet.m_flow|staCy.mixer2_1.outlet.p|staCy.mixer2_1.summary.outlet.m_flow|staCy.mixer2_1.summary.outlet.p|staCy.preheater_HP.cond_out.m_flow|staCy.preheater_HP.cond_out.p|staCy.preheater_HP.summary.outlet_cond.m_flow|staCy.preheater_HP.summary.outlet_cond.p|staCy.preheater_HP.summary.outlet_tap.h|staCy.preheater_HP.summary.outlet_tap.m_flow|staCy.preheater_HP.summary.outlet_tap.p|staCy.preheater_HP.tap_out.m_flow|staCy.preheater_HP.tap_out.p|staCy.preheater_LP1.cond_out.m_flow|staCy.preheater_LP1.cond_out.p|staCy.preheater_LP1.summary.outlet_cond.m_flow|staCy.preheater_LP1.summary.outlet_cond.p|staCy.preheater_LP1.summary.outlet_tap.h|staCy.preheater_LP1.summary.outlet_tap.m_flow|staCy.preheater_LP1.summary.outlet_tap.p|staCy.preheater_LP1.tap_out.m_flow|staCy.preheater_LP1.tap_out.p|staCy.pump_cond.outlet.m_flow|staCy.pump_cond.outlet.p|staCy.pump_cond.summary.outlet.m_flow|staCy.pump_cond.summary.outlet.p|staCy.pump_cond.summary.outline.Delta_p|staCy.pump_cond.summary.outline.P_pump|staCy.pump_fw.outlet.m_flow|staCy.pump_fw.outlet.p|staCy.pump_fw.summary.outlet.m_flow|staCy.pump_fw.summary.outlet.p|staCy.pump_fw.summary.outline.Delta_p|staCy.pump_fw.summary.outline.P_pump|staCy.split_LP.outlet_1.m_flow|staCy.split_LP.outlet_1.p|staCy.split_LP.outlet_2.m_flow|staCy.split_LP.outlet_2.p|staCy.split_LP.summary.outlet1.m_flow|staCy.split_LP.summary.outlet1.p|staCy.split_LP.summary.outlet2.m_flow|staCy.split_LP.summary.outlet2.p|staCy.split_LP1.outlet_1.m_flow|staCy.split_LP1.outlet_1.p|staCy.split_LP1.outlet_2.m_flow|staCy.split_LP1.outlet_2.p|staCy.split_LP1.summary.outlet1.m_flow|staCy.split_LP1.summary.outlet1.p|staCy.split_LP1.summary.outlet2.m_flow|staCy.split_LP1.summary.outlet2.p|staCy.split_LP_turbine2.outlet_1.m_flow|staCy.split_LP_turbine2.outlet_1.p|staCy.split_LP_turbine2.outlet_2.m_flow|staCy.split_LP_turbine2.outlet_2.p|staCy.split_LP_turbine2.summary.outlet1.m_flow|staCy.split_LP_turbine2.summary.outlet1.p|staCy.split_LP_turbine2.summary.outlet2.m_flow|staCy.split_LP_turbine2.summary.outlet2.p|staCy.turbine_HP.outlet.m_flow|staCy.turbine_HP.outlet.p|staCy.turbine_HP.summary.outlet.m_flow|staCy.turbine_HP.summary.outlet.p|staCy.turbine_HP.summary.outline.Delta_p|staCy.turbine_IP.outlet.m_flow|staCy.turbine_IP.outlet.p|staCy.turbine_IP.summary.outlet.m_flow|staCy.turbine_IP.summary.outlet.p|staCy.turbine_IP.summary.outline.Delta_p|staCy.turbine_LP1.outlet.m_flow|staCy.turbine_LP1.outlet.p|staCy.turbine_LP1.summary.outlet.m_flow|staCy.turbine_LP1.summary.outlet.p|staCy.turbine_LP1.summary.outline.Delta_p|staCy.turbine_LP2.outlet.m_flow|staCy.turbine_LP2.outlet.p|staCy.turbine_LP2.summary.outlet.m_flow|staCy.turbine_LP2.summary.outlet.p|staCy.turbine_LP2.summary.outline.Delta_p|staCy.valve.outlet.m_flow|staCy.valve.outlet.p|staCy.valve.summary.outlet.m_flow|staCy.valve.summary.outlet.p|staCy.valve1.outlet.m_flow|staCy.valve1.outlet.p|staCy.valve1.summary.outlet.m_flow|staCy.valve1.summary.outlet.p|staCy.valve2.outlet.m_flow|staCy.valve2.outlet.p|staCy.valve2.summary.outlet.m_flow|staCy.valve2.summary.outlet.p|staCy.valve_LP.outlet.m_flow|staCy.valve_LP.outlet.p|staCy.valve_LP.summary.outlet.m_flow|staCy.valve_LP.summary.outlet.p|staCy.valve_LP1.outlet.m_flow|staCy.valve_LP1.outlet.p|staCy.valve_LP1.summary.outlet.m_flow|staCy.valve_LP1.summary.outlet.p|staCy.valve_dp_nom.outlet.m_flow|staCy.valve_dp_nom.outlet.p|staCy.valve_dp_nom.summary.outlet.m_flow|staCy.valve_dp_nom.summary.outlet.p",fileNamePrefix="ClaRa_ClaRa.StaticCycles.Check.TestStacy5") translateModel(ClaRa.StaticCycles.Check.TestStacy5,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="Time|staCy.condenser.outlet.m_flow|staCy.condenser.outlet.p|staCy.condenser.summary.outlet.m_flow|staCy.condenser.summary.outlet.p|staCy.feedwatertank.cond_out.m_flow|staCy.feedwatertank.cond_out.p|staCy.feedwatertank.summary.outlet_cond.m_flow|staCy.feedwatertank.summary.outlet_cond.p|staCy.mixer2.outlet.m_flow|staCy.mixer2.outlet.p|staCy.mixer2.summary.outlet.m_flow|staCy.mixer2.summary.outlet.p|staCy.mixer2_1.outlet.m_flow|staCy.mixer2_1.outlet.p|staCy.mixer2_1.summary.outlet.m_flow|staCy.mixer2_1.summary.outlet.p|staCy.preheater_HP.cond_out.m_flow|staCy.preheater_HP.cond_out.p|staCy.preheater_HP.summary.outlet_cond.m_flow|staCy.preheater_HP.summary.outlet_cond.p|staCy.preheater_HP.summary.outlet_tap.h|staCy.preheater_HP.summary.outlet_tap.m_flow|staCy.preheater_HP.summary.outlet_tap.p|staCy.preheater_HP.tap_out.m_flow|staCy.preheater_HP.tap_out.p|staCy.preheater_LP1.cond_out.m_flow|staCy.preheater_LP1.cond_out.p|staCy.preheater_LP1.summary.outlet_cond.m_flow|staCy.preheater_LP1.summary.outlet_cond.p|staCy.preheater_LP1.summary.outlet_tap.h|staCy.preheater_LP1.summary.outlet_tap.m_flow|staCy.preheater_LP1.summary.outlet_tap.p|staCy.preheater_LP1.tap_out.m_flow|staCy.preheater_LP1.tap_out.p|staCy.pump_cond.outlet.m_flow|staCy.pump_cond.outlet.p|staCy.pump_cond.summary.outlet.m_flow|staCy.pump_cond.summary.outlet.p|staCy.pump_cond.summary.outline.Delta_p|staCy.pump_cond.summary.outline.P_pump|staCy.pump_fw.outlet.m_flow|staCy.pump_fw.outlet.p|staCy.pump_fw.summary.outlet.m_flow|staCy.pump_fw.summary.outlet.p|staCy.pump_fw.summary.outline.Delta_p|staCy.pump_fw.summary.outline.P_pump|staCy.split_LP.outlet_1.m_flow|staCy.split_LP.outlet_1.p|staCy.split_LP.outlet_2.m_flow|staCy.split_LP.outlet_2.p|staCy.split_LP.summary.outlet1.m_flow|staCy.split_LP.summary.outlet1.p|staCy.split_LP.summary.outlet2.m_flow|staCy.split_LP.summary.outlet2.p|staCy.split_LP1.outlet_1.m_flow|staCy.split_LP1.outlet_1.p|staCy.split_LP1.outlet_2.m_flow|staCy.split_LP1.outlet_2.p|staCy.split_LP1.summary.outlet1.m_flow|staCy.split_LP1.summary.outlet1.p|staCy.split_LP1.summary.outlet2.m_flow|staCy.split_LP1.summary.outlet2.p|staCy.split_LP_turbine2.outlet_1.m_flow|staCy.split_LP_turbine2.outlet_1.p|staCy.split_LP_turbine2.outlet_2.m_flow|staCy.split_LP_turbine2.outlet_2.p|staCy.split_LP_turbine2.summary.outlet1.m_flow|staCy.split_LP_turbine2.summary.outlet1.p|staCy.split_LP_turbine2.summary.outlet2.m_flow|staCy.split_LP_turbine2.summary.outlet2.p|staCy.turbine_HP.outlet.m_flow|staCy.turbine_HP.outlet.p|staCy.turbine_HP.summary.outlet.m_flow|staCy.turbine_HP.summary.outlet.p|staCy.turbine_HP.summary.outline.Delta_p|staCy.turbine_IP.outlet.m_flow|staCy.turbine_IP.outlet.p|staCy.turbine_IP.summary.outlet.m_flow|staCy.turbine_IP.summary.outlet.p|staCy.turbine_IP.summary.outline.Delta_p|staCy.turbine_LP1.outlet.m_flow|staCy.turbine_LP1.outlet.p|staCy.turbine_LP1.summary.outlet.m_flow|staCy.turbine_LP1.summary.outlet.p|staCy.turbine_LP1.summary.outline.Delta_p|staCy.turbine_LP2.outlet.m_flow|staCy.turbine_LP2.outlet.p|staCy.turbine_LP2.summary.outlet.m_flow|staCy.turbine_LP2.summary.outlet.p|staCy.turbine_LP2.summary.outline.Delta_p|staCy.valve.outlet.m_flow|staCy.valve.outlet.p|staCy.valve.summary.outlet.m_flow|staCy.valve.summary.outlet.p|staCy.valve1.outlet.m_flow|staCy.valve1.outlet.p|staCy.valve1.summary.outlet.m_flow|staCy.valve1.summary.outlet.p|staCy.valve2.outlet.m_flow|staCy.valve2.outlet.p|staCy.valve2.summary.outlet.m_flow|staCy.valve2.summary.outlet.p|staCy.valve_LP.outlet.m_flow|staCy.valve_LP.outlet.p|staCy.valve_LP.summary.outlet.m_flow|staCy.valve_LP.summary.outlet.p|staCy.valve_LP1.outlet.m_flow|staCy.valve_LP1.outlet.p|staCy.valve_LP1.summary.outlet.m_flow|staCy.valve_LP1.summary.outlet.p|staCy.valve_dp_nom.outlet.m_flow|staCy.valve_dp_nom.outlet.p|staCy.valve_dp_nom.summary.outlet.m_flow|staCy.valve_dp_nom.summary.outlet.p",fileNamePrefix="ClaRa_ClaRa.StaticCycles.Check.TestStacy5") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo): time 0.1213/0.1213, allocations: 22.37 MB / 38.14 MB, free: 2.234 MB / 26.18 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009921/0.0009926, allocations: 100.8 kB / 45.29 MB, free: 4.465 MB / 34.91 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001238/0.001238, allocations: 199.5 kB / 52.56 MB, free: 8.836 MB / 46.55 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.383/1.383, allocations: 222.9 MB / 282.6 MB, free: 2.297 MB / 206.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo): time 0.8601/0.8601, allocations: 126.8 MB / 465.8 MB, free: 12.52 MB / 366.1 MB Warning: Ignoring unknown experiment annotation option: method = "dassl" Notification: Performance of FrontEnd - loaded program: time 0.001687/0.001687, allocations: 95.69 kB / 0.5467 GB, free: 44.73 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1451/0.1468, allocations: 81.77 MB / 0.6265 GB, free: 4.148 MB / 446.1 MB Notification: Performance of NFInst.instantiate(ClaRa.StaticCycles.Check.TestStacy5): time 0.04853/0.1954, allocations: 59.73 MB / 0.6848 GB, free: 8.242 MB / 0.4982 GB Notification: Performance of NFInst.instExpressions: time 0.03849/0.234, allocations: 28.66 MB / 0.7128 GB, free: 11.47 MB / 0.5294 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.009722/0.2438, allocations: 195.4 kB / 0.713 GB, free: 11.28 MB / 0.5294 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/StaticCycles/Triple.mo:32:3-32:182:writable] Warning: Connector steamSignal is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.004536/0.2483, allocations: 1.735 MB / 0.7147 GB, free: 9.539 MB / 0.5294 GB Notification: Performance of NFTyping.typeBindings: time 0.005565/0.2539, allocations: 1.838 MB / 0.7165 GB, free: 7.691 MB / 0.5294 GB Notification: Performance of NFTyping.typeClassSections: time 0.001929/0.2558, allocations: 0.7006 MB / 0.7172 GB, free: 7 MB / 0.5294 GB Notification: Performance of NFFlatten.flatten: time 0.00566/0.2615, allocations: 4.643 MB / 0.7217 GB, free: 2.352 MB / 0.5294 GB Notification: Performance of NFFlatten.resolveConnections: time 0.002332/0.2639, allocations: 1.833 MB / 0.7235 GB, free: 460 kB / 0.5294 GB Notification: Performance of NFEvalConstants.evaluate: time 0.004097/0.268, allocations: 2.41 MB / 0.7259 GB, free: 14.03 MB / 0.545 GB Notification: Performance of NFSimplifyModel.simplify: time 0.003439/0.2714, allocations: 2.072 MB / 0.7279 GB, free: 11.95 MB / 0.545 GB Notification: Performance of NFPackage.collectConstants: time 0.0007017/0.2721, allocations: 240 kB / 0.7281 GB, free: 11.71 MB / 0.545 GB Notification: Performance of NFFlatten.collectFunctions: time 0.003709/0.2759, allocations: 1.299 MB / 0.7294 GB, free: 10.43 MB / 0.545 GB Notification: Performance of NFScalarize.scalarize: time 0.001503/0.2774, allocations: 1.397 MB / 0.7308 GB, free: 9.023 MB / 0.545 GB Notification: Performance of NFVerifyModel.verify: time 0.003283/0.2807, allocations: 2.272 MB / 0.733 GB, free: 6.738 MB / 0.545 GB Notification: Performance of NFConvertDAE.convert: time 0.006268/0.2869, allocations: 5.707 MB / 0.7385 GB, free: 1.02 MB / 0.545 GB Notification: Performance of FrontEnd - DAE generated: time 6.963e-06/0.287, allocations: 0 / 0.7385 GB, free: 1.02 MB / 0.545 GB Notification: Performance of FrontEnd: time 1.734e-06/0.287, allocations: 0 / 0.7385 GB, free: 1.02 MB / 0.545 GB Notification: Performance of Transformations before backend: time 0.000129/0.2871, allocations: 0 / 0.7385 GB, free: 1.02 MB / 0.545 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 217 * Number of variables: 217 Notification: Performance of Generate backend data structure: time 0.01088/0.298, allocations: 5.701 MB / 0.7441 GB, free: 11.23 MB / 0.5607 GB Notification: Performance of prepare preOptimizeDAE: time 4.667e-05/0.2981, allocations: 8.031 kB / 0.7441 GB, free: 11.22 MB / 0.5607 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.001258/0.2993, allocations: 0.5802 MB / 0.7447 GB, free: 10.63 MB / 0.5607 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.009853/0.3092, allocations: 6.405 MB / 0.7509 GB, free: 4.148 MB / 0.5607 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 8.493e-05/0.3093, allocations: 97.94 kB / 0.751 GB, free: 4.051 MB / 0.5607 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0001472/0.3095, allocations: 124 kB / 0.7512 GB, free: 3.93 MB / 0.5607 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.002329/0.3118, allocations: 2.234 MB / 0.7533 GB, free: 1.012 MB / 0.5607 GB Notification: Performance of preOpt findStateOrder (simulation): time 2.856e-05/0.3118, allocations: 15.88 kB / 0.7534 GB, free: 0.9961 MB / 0.5607 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001196/0.312, allocations: 64 kB / 0.7534 GB, free: 0.9336 MB / 0.5607 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 5.941e-05/0.312, allocations: 55.86 kB / 0.7535 GB, free: 0.8789 MB / 0.5607 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.0009934/0.313, allocations: 0.6821 MB / 0.7541 GB, free: 200 kB / 0.5607 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.2819/0.5949, allocations: 12.07 MB / 0.7659 GB, free: 108 MB / 0.5607 GB Notification: Performance of preOpt comSubExp (simulation): time 0.00112/0.5961, allocations: 1.916 MB / 0.7678 GB, free: 105.6 MB / 0.5607 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.0008868/0.597, allocations: 1.027 MB / 0.7688 GB, free: 104.7 MB / 0.5607 GB Notification: Performance of preOpt evalFunc (simulation): time 9.401e-05/0.5971, allocations: 58.67 kB / 0.7689 GB, free: 104.7 MB / 0.5607 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0001063/0.5972, allocations: 162.2 kB / 0.769 GB, free: 104.6 MB / 0.5607 GB Notification: Performance of pre-optimization done (n=111): time 5.56e-06/0.5972, allocations: 0 / 0.769 GB, free: 104.6 MB / 0.5607 GB Notification: Performance of matching and sorting (n=111): time 0.005912/0.6031, allocations: 2.156 MB / 0.7711 GB, free: 104 MB / 0.5607 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.000416/0.6036, allocations: 2.369 MB / 0.7734 GB, free: 101.1 MB / 0.5607 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.008885/0.6124, allocations: 6 MB / 0.7793 GB, free: 98.95 MB / 0.5607 GB Notification: Performance of collectPreVariables (initialization): time 0.0002008/0.6127, allocations: 66.67 kB / 0.7793 GB, free: 98.89 MB / 0.5607 GB Notification: Performance of collectInitialEqns (initialization): time 0.0011/0.6138, allocations: 1.353 MB / 0.7807 GB, free: 97.84 MB / 0.5607 GB Notification: Performance of collectInitialBindings (initialization): time 0.0003479/0.6141, allocations: 427.4 kB / 0.7811 GB, free: 97.62 MB / 0.5607 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.001624/0.6158, allocations: 1.15 MB / 0.7822 GB, free: 96.9 MB / 0.5607 GB Notification: Performance of setup shared object (initialization): time 4.473e-05/0.6158, allocations: 301.1 kB / 0.7825 GB, free: 96.61 MB / 0.5607 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.001602/0.6174, allocations: 1.111 MB / 0.7836 GB, free: 96.06 MB / 0.5607 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.001706/0.6191, allocations: 1.468 MB / 0.785 GB, free: 95.22 MB / 0.5607 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.002086/0.6212, allocations: 1.974 MB / 0.7869 GB, free: 94.16 MB / 0.5607 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 8.166e-06/0.6212, allocations: 3.969 kB / 0.7869 GB, free: 94.16 MB / 0.5607 GB Notification: Performance of matching and sorting (n=532) (initialization): time 0.005206/0.6265, allocations: 3.801 MB / 0.7906 GB, free: 92.35 MB / 0.5607 GB Notification: Performance of prepare postOptimizeDAE: time 1.946e-05/0.6265, allocations: 4.469 kB / 0.7907 GB, free: 92.35 MB / 0.5607 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 1.346e-05/0.6265, allocations: 4 kB / 0.7907 GB, free: 92.35 MB / 0.5607 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0008822/0.6274, allocations: 330.7 kB / 0.791 GB, free: 92.21 MB / 0.5607 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.001864/0.6293, allocations: 0.7803 MB / 0.7917 GB, free: 92.04 MB / 0.5607 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.003928/0.6332, allocations: 3.524 MB / 0.7952 GB, free: 88.81 MB / 0.5607 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.002128/0.6353, allocations: 285.1 kB / 0.7954 GB, free: 88.6 MB / 0.5607 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0001533/0.6355, allocations: 136 kB / 0.7956 GB, free: 88.47 MB / 0.5607 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 16 * Number of states: 0 () * Number of discrete variables: 5 (staCy.valve_dp_nom.table1.tableID,staCy.valve_LP1.table1.tableID,staCy.valve_LP.table1.tableID,staCy.boiler.table2.tableID,staCy.boiler.table1.tableID) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (493): * Single equations (assignments): 492 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(1,39)} Notification: Performance of prepare postOptimizeDAE: time 0.001495/0.637, allocations: 1.185 MB / 0.7967 GB, free: 87.27 MB / 0.5607 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.001776/0.6388, allocations: 0.5207 MB / 0.7972 GB, free: 86.75 MB / 0.5607 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.0009379/0.6397, allocations: 0.9108 MB / 0.7981 GB, free: 85.81 MB / 0.5607 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 1.961e-05/0.6398, allocations: 28 kB / 0.7982 GB, free: 85.78 MB / 0.5607 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.112e-05/0.6398, allocations: 24 kB / 0.7982 GB, free: 85.76 MB / 0.5607 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 1.971e-05/0.6398, allocations: 31.97 kB / 0.7982 GB, free: 85.73 MB / 0.5607 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.009496/0.6493, allocations: 11.83 MB / 0.8098 GB, free: 73.55 MB / 0.5607 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.381e-05/0.6493, allocations: 28 kB / 0.8098 GB, free: 73.52 MB / 0.5607 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.0003557/0.6497, allocations: 195.6 kB / 0.81 GB, free: 73.33 MB / 0.5607 GB Notification: Performance of postOpt tearingSystem (simulation): time 1.677e-05/0.6497, allocations: 31.94 kB / 0.81 GB, free: 73.3 MB / 0.5607 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 4.118e-05/0.6498, allocations: 44.5 kB / 0.8101 GB, free: 73.25 MB / 0.5607 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 1.856e-05/0.6498, allocations: 43.8 kB / 0.8101 GB, free: 73.21 MB / 0.5607 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.246e-05/0.6498, allocations: 32.64 kB / 0.8101 GB, free: 73.18 MB / 0.5607 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.001406/0.6512, allocations: 2.242 MB / 0.8123 GB, free: 70.62 MB / 0.5607 GB Notification: Performance of postOpt removeConstants (simulation): time 0.001212/0.6524, allocations: 1.241 MB / 0.8135 GB, free: 69.37 MB / 0.5607 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.000372/0.6528, allocations: 55.97 kB / 0.8136 GB, free: 69.32 MB / 0.5607 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.001058/0.6539, allocations: 32 kB / 0.8136 GB, free: 69.29 MB / 0.5607 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 8.596e-05/0.654, allocations: 143.3 kB / 0.8137 GB, free: 69.14 MB / 0.5607 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 4.361e-05/0.654, allocations: 61.19 kB / 0.8138 GB, free: 69.09 MB / 0.5607 GB Notification: Performance of sorting global known variables: time 0.004118/0.6582, allocations: 3.984 MB / 0.8177 GB, free: 65.11 MB / 0.5607 GB Notification: Performance of sort global known variables: time 1.5e-07/0.6582, allocations: 0 / 0.8177 GB, free: 65.11 MB / 0.5607 GB Notification: Performance of remove unused functions: time 0.002089/0.6603, allocations: 0.9286 MB / 0.8186 GB, free: 64.21 MB / 0.5607 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 98 * Number of states: 0 () * Number of discrete variables: 5 (staCy.boiler.table1.tableID,staCy.boiler.table2.tableID,staCy.valve_LP.table1.tableID,staCy.valve_LP1.table1.tableID,staCy.valve_dp_nom.table1.tableID) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (105): * Single equations (assignments): 100 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.001991/0.6623, allocations: 1.11 MB / 0.8197 GB, free: 63.64 MB / 0.5607 GB Notification: Performance of simCode: created initialization part: time 0.003169/0.6654, allocations: 2.381 MB / 0.822 GB, free: 61.25 MB / 0.5607 GB Notification: Performance of simCode: created event and clocks part: time 1.047e-05/0.6655, allocations: 4 kB / 0.822 GB, free: 61.25 MB / 0.5607 GB Notification: Performance of simCode: created simulation system equations: time 0.0004664/0.6659, allocations: 472.6 kB / 0.8225 GB, free: 60.79 MB / 0.5607 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.003287/0.6692, allocations: 0.5185 MB / 0.823 GB, free: 60.29 MB / 0.5607 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.009243/0.6785, allocations: 8.989 MB / 0.8318 GB, free: 50.97 MB / 0.5607 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.001672/0.6802, allocations: 2.514 MB / 0.8342 GB, free: 48.43 MB / 0.5607 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.000847/0.681, allocations: 315.2 kB / 0.8345 GB, free: 48.12 MB / 0.5607 GB Notification: Performance of SimCode: time 1.142e-06/0.681, allocations: 4 kB / 0.8345 GB, free: 48.11 MB / 0.5607 GB Notification: Performance of Templates: time 0.056/0.7371, allocations: 54.4 MB / 0.8876 GB, free: 10.07 MB / 0.5763 GB make -j1 -f ClaRa_ClaRa.StaticCycles.Check.TestStacy5.makefile make -j1 -f ClaRa_ClaRa.StaticCycles.Check.TestStacy5.makefile clang++ -std=c++14 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/include/omc/sundials" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5CalcHelperMain.o OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5CalcHelperMain.cpp In file included from OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5CalcHelperMain.cpp:28: ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:271:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:88:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:297:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:87:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:323:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:88:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:349:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:87:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:375:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:88:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:401:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:87:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:788:12: error: use of undeclared identifier 'TILMedia_redirectModelicaFormatMessage_wrapper' x__ext = TILMedia_redirectModelicaFormatMessage_wrapper(); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:815:25: error: use of undeclared identifier 'TILMedia_createExternalObject' externalObject__ext = TILMedia_createExternalObject(objectType_.c_str(), mediumName_.c_str(), flags__ext, ConstArray(xi_).getData(), nc__ext, condensingIndex__ext, instanceName_.c_str()); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:858:19: error: no matching function for call to 'TILMedia_VLEFluidFunctions_bubbleDensity_pxi' d_bubble__ext = TILMedia_VLEFluidFunctions_bubbleDensity_pxi(p__ext, ConstArray(xi_).getData(), vleFluidName_.c_str(), nc__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:10:8: note: candidate function not viable: 2nd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidFunctions_bubbleDensity_pxi(double, double*, const char*, int); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:882:19: error: no matching function for call to 'TILMedia_VLEFluidFunctions_bubbleSpecificEnthalpy_pxi' h_bubble__ext = TILMedia_VLEFluidFunctions_bubbleSpecificEnthalpy_pxi(p__ext, ConstArray(xi_).getData(), vleFluidName_.c_str(), nc__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:9:8: note: candidate function not viable: 2nd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidFunctions_bubbleSpecificEnthalpy_pxi(double, double*, const char*, int); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:908:12: error: no matching function for call to 'TILMedia_VLEFluidFunctions_density_phxi' d__ext = TILMedia_VLEFluidFunctions_density_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidName_.c_str(), nc__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:8:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidFunctions_density_phxi(double, double, double*,const char*, int); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:934:12: error: no matching function for call to 'TILMedia_VLEFluidFunctions_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluidFunctions_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidName_.c_str(), nc__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:7:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidFunctions_specificEnthalpy_pTxi(double, double, double*,const char*, int); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:960:12: error: no matching function for call to 'TILMedia_VLEFluidFunctions_specificEnthalpy_psxi' h__ext = TILMedia_VLEFluidFunctions_specificEnthalpy_psxi(p__ext, s__ext, ConstArray(xi_).getData(), vleFluidName_.c_str(), nc__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidFunctions_specificEnthalpy_psxi(double, double, double*,const char*, int); ^ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:986:12: error: no matching function for call to 'TILMedia_VLEFluidFunctions_specificEntropy_phxi' s__ext = TILMedia_VLEFluidFunctions_specificEntropy_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidName_.c_str(), nc__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5Functions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidFunctions_specificEntropy_phxi(double, double, double*,const char*, int); ^ 14 errors generated. make: *** [: OMCppClaRa_ClaRa.StaticCycles.Check.TestStacy5CalcHelperMain.o] Error 1