Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo", uses=false) Using package BuildSysPro with version 3.5.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=16,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=16,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001045/0.001045, allocations: 100.1 kB / 15.88 MB, free: 12 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001111/0.001111, allocations: 198.5 kB / 16.79 MB, free: 6.809 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.378/1.378, allocations: 222.9 MB / 240.5 MB, free: 4.598 MB / 190.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/Building/BuildingEnvelope/HeatTransfer/package.mo:2:1-40:17:writable] Warning: Soil_case_nappe was referenced in the package.order file, but was not found in package.mo, Soil_case_nappe/package.mo or Soil_case_nappe.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo): time 0.9985/0.9985, allocations: 143 MB / 433.7 MB, free: 11.63 MB / 350.1 MB Notification: Performance of FrontEnd - loaded program: time 0.001695/0.001695, allocations: 59.91 kB / 0.5141 GB, free: 12.17 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1927/0.1944, allocations: 82.03 MB / 0.5942 GB, free: 10.11 MB / 0.4981 GB Notification: Performance of NFInst.instantiate(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler): time 0.004151/0.1986, allocations: 2.363 MB / 0.5966 GB, free: 7.73 MB / 0.4981 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/BaseClasses/Media/OLD_THERMHYGAERO/AirFunctions/Psat.mo:3:3-3:24:writable] Error: Invalid public variable AH, function variables that are not input/output must be protected. Notification: Performance of FrontEnd: time 0.001143/0.1998, allocations: 0.4907 MB / 0.597 GB, free: 7.238 MB / 0.4981 GB