Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4") translateModel(ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.7421/0.7421, allocations: 150.8 MB / 166.1 MB, free: 15.43 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 1.518e-05/1.509e-05, allocations: 0 / 204.8 MB, free: 10.05 MB / 174.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1346/0.1346, allocations: 31.97 MB / 236.8 MB, free: 5.41 MB / 190.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4): time 1.421/1.556, allocations: 293.7 MB / 0.518 GB, free: 13.36 MB / 414.1 MB Notification: Performance of NFInst.instExpressions: time 0.03305/1.589, allocations: 33.39 MB / 0.5506 GB, free: 12.1 MB / 446.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0002219/1.589, allocations: 4 kB / 0.5506 GB, free: 12.1 MB / 446.1 MB Notification: Performance of NFTyping.typeComponents: time 0.0002684/1.59, allocations: 75.56 kB / 0.5507 GB, free: 12.02 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert. Notification: Performance of FrontEnd: time 9.021e-05/1.59, allocations: 45.83 kB / 0.5507 GB, free: 11.98 MB / 446.1 MB