Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.0002 Regular simulation: ./Modelica_4.0.0_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTapmPulse.ThyristorCenterTapmPulse_R -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00530558s reading init.xml | | | | | | 0.000480311s reading info.xml | | | | | | 0.000605035s [ 3.0%] pre-initialization | | | | | | 0.000187953s [ 0.9%] initialization | | | | | | 1.1602e-05s [ 0.1%] steps | | | | | | 0.00203423s [ 10.2%] solver (excl. callbacks) | | | | | | 0.000604184s [ 3.0%] creating output-file | | | | | | 0.00828148s [ 41.7%] event-handling | | | | | | 0.000183362s [ 0.9%] overhead | | | | | | 0.00796053s [ 40.1%] simulation | | | | | | 0.0198684s [100.0%] total | | | | | events | | | | | | 89 state events | | | | | | 15 time events | | | | | solver: dassl | | | | | | 2219 steps taken | | | | | | 2683 calls of functionODE | | | | | | 1119 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00115633s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.